My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Hardesty & Hanover
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
RFQ
>
(19-11-01) Prof Eng and Arch Srvcs Ped Bridge REVISED
>
Responses
>
Hardesty & Hanover
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/14/2020 3:56:17 PM
Creation date
1/14/2020 3:49:08 PM
Metadata
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
391
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'SQUALIFICATIONS FOR THIS CONTRACT (Present as many projects as requested by the agency, or 10 projects, if not specified. Complete one Section F for each project.) <br />a. PROJECT OWNER <br />21. TITLE AND LOCATION (City and State) <br />25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT <br />24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost) <br />20. EXAMPLE PROJECT KEY <br />NUMBER <br />a. <br />b. <br />c. <br />d. <br />e. <br />f. <br />(1) FIRM NAME (2) FIRM LOCATION (City and State) <br />(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State) <br />(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State) <br />(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State) <br />STANDARD FORM 330 (REV. 8/2016) PAGE 3 <br />(3) ROLE <br />(1) FIRM NAME (2) FIRM LOCATION (City and State)(3) ROLE <br />b. POINT OF CONTACT NAME <br />23. PROJECT OWNER'S INFORMATION <br />c. POINT OF CONTACT TELEPHONE NUMBER <br />(3) ROLE(1) FIRM NAME (2) FIRM LOCATION (City and State) <br />22. YEAR COMPLETED <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />The City of Miami Beach Public Works Department retained UES to prepare geotechnical documents to be in- <br />cluded in the design-criteria package for a design-build letting. The project includes the installation of approx- <br />imately 5,300 linear feet of force main with minimum internal diameter of 54 inches. The proposed pipeline will <br />have approximately 4,600 linear feet of micro-tunnel along the urban corridor of Euclid Avenue and Washing- <br />ton Avenue. Approximately 600 linear feet of the force main will be installed by means of open-cut method at <br />the terminal locations of the project along Washington Avenue and 11th Street to accomplish the final connec- <br />tions to the existing pipelines. <br />UES was retained by the CMBPWD to prepare the Geotechnical Data Report (GDR) and Geotechnical Baseline <br />Report (GBR) for the pipeline installation. The GDR scope of services included performing eight Standard Pene- <br />tration Test (SPT) borings to depths of 40 feet in areas of micro-tunneling, two SPT borings to depths of 20 feet <br />in areas of open-cut installation, five rock coring locations in areas of micro-tunnel installation and performed <br />two slug tests to evaluate the subsurface hydrogeology. The laboratory testing program included visual soil/ <br />rock classification in tunneling standards, moisture content, grain-size distribution, organic content determina- <br />tion, corrosion series testing, rock unconfined compressive strength testing and rock tensile strength testing. <br />54-Inch Diameter Redundant Force Main (Miami Beach, Florida)12/2014 N/A <br />City of Miami Beach Bruce Mowry, PhD, PE 305.673.7071 <br />Universal Engineering Sciences Miami, Florida Geotechnical Field Exploration, Sampling, <br />and Laboratory Testing
The URL can be used to link to this page
Your browser does not support the video tag.