E-19Proven solutionsResponsive and dependable performance
<br />City of Sunny Isles Beach RFQ No. 20-07-01: Continuing Professional Consulting Services (CCNA)
<br />B.
<br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED
<br />Wastewater Collection Systems, Various Locations, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
<br />2020 Ongoing
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm
<br />Project/Program Manager for management and design of a variety of wastewater pump/lift stations and collection
<br />systems involving clay, PVC, ductile iron, HDPE, Drisco, and prestressed and reinforced concrete pipe for sewers ranging
<br />from municipal sanitary to industrial ink press washwater to papermill acid. Lead civil design engineer for an entire
<br />nuclear power plant site, two auto assembly plants (Buick Division of GM) and numerous office/commercial complexes
<br />and residential subdivisions. Was integrally involved in the review, design, repair, rehabilitation, installation, and QA/QC of
<br />various pump/lift/pump stations for sanitary and industrial sewer systems, which included civil, structural, mechanical and
<br />electrical disciplines, and the use of trenchless technologies, horizontal directional drilling, slip-lining, pipe-bursting and
<br />traditional dig-and-replace construction methods. Designed and installed various types and depths of manholes involving
<br />sealants, coatings and water-tight products.
<br />C.
<br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED
<br />MDWASD Pump Station Improvement Program (PSIP) & Associated
<br />Force Mains, Miami-Dade County, FL
<br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
<br />Ongoing Ongoing
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm
<br />As Project Director/Technical Advisor, provided project oversight and guidance for scope and fee development, client
<br />coordination, site & system evaluation for cost, engineering analysis, design, coordination, permitting and management for
<br />the rehabilitation and replacement of multiple pump stations for the PSIP. The project consisted of existing pump station
<br />inspection, coordination of survey and geotechnical services, design of pump station rehabilitation or replacement, design
<br />of connecting force mains, permitting, and limited construction services. The engineering work included PS 0449, PS 0147,
<br />PS 0331, Force Main 0592 (24-inch), PS 0440, PS 0336, PS 0609, PS 0081, PS 1026 and PS 1065.
<br />D.
<br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED
<br />NW 12th Avenue Force Main Replacement, North Miami, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
<br />2019
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm
<br />QA/QC for the design, permitting, and construction of 10,500 LF of 10- and 12-inch replacement force main in NW 12th
<br />Avenue extending from NW 95th Street to NW 125th Street. The project replaced aging, asbestos-cement and cast iron force
<br />mains with corrosion resistant PVC pipe. A number of private force main connections required relocation and reconnection
<br />to the new force main, as well as planning for uninterrupted service during construction.
<br />E.
<br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED
<br />Water Distribution Systems, Various Locations, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
<br />Ongoing Ongoing
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm
<br />Program/Project Manager for management and design of water distribution and treatment systems for residential
<br />subdivisions, office complexes, shopping malls, small cities, municipal improvements/ rehabilitations, major airports and
<br />U.S. Corps of Engineers. Projects included hydraulic modeling and system evaluation; large diameter and raw water intake
<br />piping and structures; 18” - 48” transmission mains; private and public distribution piping; pumping stations; 250,000-gallon
<br />to 5-MG water storage tanks (ground and elevated); and treatment plant expansion/ modifications involving reverse
<br />osmosis, sand and media filters, clear wells, lime softening facilities and flocculation basins.
<br />F.
<br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED
<br />Palm Beach County Water Utilities Department Looping Project,
<br />Palm Beach County, FL
<br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
<br />2018 2019
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm
<br />QA/QC for the rehabilitation of 16,000 LF of water main pipelines of varying sizes from 4” to 12” including DIP, PVC and
<br />HDPE at 19 locations across Palm Beach County. Installation of the new segments of waterline and new interconnections
<br />improved system capacity and hydraulic efficiencies, eliminated dead-ends, and reduced water retention time, resulting in
<br />improved water quality. Directional Drilling was designed for major intersections and tree lined corridors.
<br />STANDARD FORM 330 (REV. 8/2016) PAGE 2
|