CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2021-3192
Date (mm/dd/yyyy)
05/20/2021
Description
Change Order No. 8 w/Nunez Construction for Gateway Park
Supplemental fields
Comment
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
40
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Miami -Dade County <br />9- CONTACT- YOANDRY GALAN - 305-300-3750 <br />-- --- 10- FOR TCO APPT CALL 786-315-2771, TAKE THIS FORM AND YOUR <br />TCO FORM FROM CITY AND LETTER OF HARDSHIP. <br />SRI FEES APPLY <br />LT. GUILER <br />Date: Inspector: <br />2/12/2021 Tina Guiler (TINAG) <br />PERMIT #2019052832 <br />151 SUNNY ISLES BLVD <br />2/12/2021 <br />Type: <br />208 - FIRE TCO <br />INSPECTION <br />SUB PERMITS - <br />FIRE SPK- #20034591 -APPROVED <br />F/A - #2020058368- PARTIAL APPROVAL <br />F/A ACCESS CONTROL- ? <br />FIRE TCO INSPECTION NOT APPROVED <br />Status: <br />3 - REJECTED NOT TO <br />CODE <br />1- PROVIDE A FULL SET OF APPROVED PLANS FOR NEXT <br />INSPECTION. COPIES ARE NOT ACCEPTED FOR FIRE INSPECTION. <br />NFPA 1:1.14.1 <br />2- PROVIDE CORRECT SIGNAGE FOR FDC BY FACP ROOM ON <br />NORTH SIDE OF BLDG. SIGNAGE NEEDS TO STATE, SPELLED OUT - <br />FIRE DEPARTMENT CONNECTION, NO PARKING, AND PROVIDE <br />ADDRESS ON SIGN. SIGN REQUIERED TO BE 7 FEET IN HEIGHT. <br />NFPA 13:8.17.2.4.7. PROVIDE CAPS FOR FDC. THEY ARE MISSING. <br />3- PROVIDE LOCK FOR CHAIN AT BACKFLOW SOUTH WEST <br />CORNER. NFPA 25:12.6.2. <br />4- REPLACE ALL PAINTED SPRINKLER ESCUTCHEON PLATES FOR <br />ALL THE NORTH CORRIDOR BY ELECTRCIAL PANEL ROOMS. <br />NFPA 13:6.2.7.2. <br />5- NEED TO PULL FIRE PERMIT FOR ACCESS CONTROL, CARD <br />READERS, INSTALLED. PROVIDE APPROVED STAMPED PLANS BY <br />FIRE AND NEED TO TEST. NFPA 101:7.2.1.6.2. <br />6- EM LIGHTS TESTED & KISOK AREA ONLY IS OKAY, WORKSTATION <br />AREA NOT WORKING. NEED TO RE -TEST EM LIGHTS EVERYWHERE <br />BUT KIOSK AREA. EXIT SIGN MARKED ON PLANS NEEDS TO BE <br />LOWERED SO, YOU CAN SEE THE EXIT SIGN. ADD 2 EXIT SIGNS IN <br />STORAGE AREA MARKED ON PLANS, AS PER PLANS STATE. & <br />)ldgadmin.miamidade.gov/MDFR/CommentRpt.asp?Permit=2019052832&flag=View 2/4 <br />