Laserfiche WebLink
r. <br />19. RELEVANT PROJECTS (CONT.) <br />p. <br />o. <br />n. <br />q. <br />(1) TITLE AND LOCATION (City and State) <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />(2) YEAR COMPLETED <br />Check if project performed with current firmX <br />(1) TITLE AND LOCATION (City and State) <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />(2) YEAR COMPLETED <br />Check if project performed with current firmX <br />(1) TITLE AND LOCATION (City and State) <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />(2) YEAR COMPLETED <br />Check if project performed with current firmX <br />(1) TITLE AND LOCATION (City and State) <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />(2) YEAR COMPLETED <br />Check if project performed with current firmX <br />(1) TITLE AND LOCATION (City and State) <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />(2) YEAR COMPLETED <br />Check if project performed with current firmX <br />STANDARD FORM 330 (REV. 8/2016) - SF330 NichOlAS KANeliDiS <br />lift Station No. 9 Rehabilitation <br />Davie, Florida <br />Project Manager for a municipal sewer pump station rehabilitation. The existing pumps failed when the mechanical room flooded with <br />sewage backflow from the adjacent wet well. Since the station was being operated 24 hrs/day by a portable diesel-powered bypass pump <br />in a residential neighborhood, it quickly became a priority project for the Town. The project was unique in that the station is located within <br />Hollywood. Therefore, additional coordination was required between the two municipalities for permitting and construction scheduling. <br />The project scope included site visit documentation, pump manufacturer coordination and specifications, sewer flow analysis, hydraulic <br />calculations, ventilation system sizing, electrical and instrumentation, sump pump and piping replacement, cost estimating, permitting, <br />preparation of contract documents for bidding, addressing Bidder RFI’s, evaluating submitted bids, shop drawings reviews, addressing <br />Contractor RFI’s, reviewing and negotiating change orders, construction inspections, reviewing as-builts, and final project certification. <br />2017 - 2018 2018 <br />Sewer Pump Station B-10 Rehabilitation <br />Fort Lauderdale, Florida <br />Project Manager for a municipal sewer pump station rehabilitation project. The existing pumps were reaching the end of their service <br />life, and the existing concrete wet well was consistently leaking into the dry mechanical room. Coordinating with the neighboring <br />residents, designating equipment staging areas, and determining proper MOT were crucial, since the station is located in the median of <br />the road. Tasks included analyzing existing flow and pressure conditions, hydraulic calculations, specifying new pumps, new electrical <br />and ventilation design, permitting, preparing technical specifications, bidding assistance, addressing Contractor RFI’s, reviewing shop <br />drawings, conducting routine inspections, reviewing and negotiating change orders, as-built reviews, and final project certification. <br />2015 - 2019 2017 - 2019 <br />Sewer Pump Station D-41 Replacement <br />Fort Lauderdale, Florida <br />PM for a municipal sewer main & PS replacement. Upgrades to the station’s operating capacity were needed due to excessive flows, <br />frequent surcharging, & accommodation for future development sewer contributions. The scope entailed replacement & relocation of <br />existing station & redirection of gravity sewer conveyance network. Coordination played a key role in this project as the proposed location <br />for the PS & design of the new sewer main had to be planned with the neighboring development & their design team. Specific project <br />tasks included analysis of existing sewer flow contributions, review of existing force main pressures, hydraulic calculations for designing <br />new force main & submersible pumps, valve vault design, electrical & instrumentation design, permitting, coordinating with other <br />disciplines including Geotechnical & SUE, preparing technical specifications, bidding assistance, addressing Contractor RFI’s, reviewing <br />& negotiating change orders, shop drawing reviews, conducting routine inspections, reviewing as-builts, & final project certification. <br />2015 - 2018 2017 - 2018 <br />Bayshore Drive Drainage improvements <br />Fort Lauderdale, Florida <br />Project Manager for the analysis and design of drainage system improvements in the Central Beach Alliance Neighborhood located off <br />A1A. The scope included preparation of a drainage model for existing site conditions by using ICPR and utilizing survey, record drawings, <br />and LIDAR for calibration. A full drainage report summarized the different options for improvements in the area with associated costs. <br />Some of the proposed alternatives included exfiltration trenches, drainage injection wells, and tidal check valves. Ultimately, the City <br />tasked CGA to design tidal check valves on the outfall pipes and additional stormwater structures and conveyance piping in areas with <br />significant ponding. layout. Additionally, the City requested traffic improvements by the addition of a median at the unique intersection of <br />Bayshore Drive, Riomar Street, and Antioch Avenue. CGA also provided typical services during construction. <br />2014 - 2019 2016 - 2019 <br />Bid Pack 8 infrastructure improvements <br />Oakland Park, Florida <br />Project Engineer for the water and sewer improvements project. Design included approximately 18,000 linear feet of water main <br />replacement, 800 linear feet of drainage with exfiltration trench, 2,500 linear feet of sidewalk, rehabilitation of a sewer pump station, and <br />installation of four sewer combination air valves (SCAV) on the existing force main network. The system upgrades consisted of replacing <br />two-inch and four-inch diameter water main with either six-inch or eight-inch PVC or DIP. Additional fire hydrants were designed to <br />provide adequate fire protection for the residential neighborhoods. In addition to these water main improvements and SCAV’s, the sewer <br />pump station improvements were a critical component of this project. The station was experiencing failure due to extended run times <br />because of increases in collected wastewater flows and discharge force main pressures. Electrical upgrades and the design of variable <br />frequency drives were required to handle the various flow conditions. <br />2014 - 2018 2018 - 2019 <br />57