Laserfiche WebLink
Ms. Genesis Cuevas <br />CTA Proposal No. 2018-UO3.383 (Revised) <br />July 18, 2019 <br />Page 6 <br />equipment to the extent possible. In addition, CTA shall identify proposed easements <br />required to accommodate additional above -grade improvements. CTA assumes most <br />underground features to be located within the right-of-way with the occasional <br />exception for larger equipment and service connections. <br />2.3 Prepare Design Development Plans <br />Based upon input on Preliminary plans from FP&L and utility providers, CTA shall <br />incorporate individual design improvements into the Underground Plan. Once updated <br />CTA will redistribute to all utilities for confirmation and further coordination. <br />2.4 Prepare Easement Descriptions <br />Most of the proposed equipment is assumed to be placed within the public right-of- <br />way. However, there will be occasion for some equipment to be placed on private <br />and/or public property therefore requiring an easement dedication. Based upon <br />information coordinated with the' utility requesting the easement, CTA shall provide <br />specific purpose survey and sketch and legal description of the easement. Pursuit of <br />easement dedication and/or processing/recording of the easement is by the City. <br />Although the exact number of easements cannot be determined without plans, based <br />upon preliminary information from FPL, it is anticipated that fifteen (15) easements will <br />be required. Preparation of individual sketches with legal descriptions of each FPL <br />Equipment Site that are ready for recording purposes in the Public records of Miami <br />Dade County. <br />Approximate time of completion: two -three (2-3) weeks after Task 1.1.b is completed. <br />2.5 Site Lighting Plan <br />With removal of the overhead lines, existing power -poles and attached lighting will be <br />removed. It is the City's intent to replace the existing lighting with decorative poles <br />more evenly distributed throughout the neighborhood. With assistance from Hillers <br />Electrical Engineering (HEE), a lighting plan shall be prepared. Plan will be based upon <br />fixture and criteria established by City. Service to lighting will be established with FPL <br />and coordinated through the undergrounding plans. <br />2.6 Prepare Construction Documents <br />Based upon input from Design Development plans from FP&L and utility providers, CTA <br />shall refine the Underground Plan into Construction Documents (CD's). Plans shall <br />incorporate sufficient detail for construction of proposed improvements and be used as <br />basis for bids and permits. With permit approvals, plans will progress to 100% CD's. <br />CRRIEN. IROMPSON & ASSOCIMES INC <br />