Laserfiche WebLink
<br />City of Sunny Isles Beach |Request for Proposal No. 22-04-01 39 <br /> <br />Optical fiber connectors shall satisfy all interface parameters of equipment components as may be defined <br />by the transmission equipment specifications. All optical fiber connector assemblies shall be machine <br />angle polished for low back-reflection and low insertion losses at both 1310 nm and 1550 nm wavelengths. <br />Single-mode pigtails shall be provided with factory pre-connectorized single-mode connectors of the "LC <br />Angle-PC" type. Connectors shall have maximum insertion loss of 0.5 dB or better. Connectors shall have <br />a composite barrel with a “push-pull” connection design, ceramic (zirconia) ferrule. Each connector shall <br />be capable of 200 repeated matings with a total maximum additional increase in insertion loss after 200 <br />matings limited to 0.30 dB. <br />Each connector shall have a return loss (back reflection) equal to or better than .50 dB. <br />All connectors shall be factory-assembled and tested. There shall be no fabrication of connectors in the <br />field. <br />All unmated connectors shall have protective caps installed. <br />4.8 Couplers <br />Couplers shall be made of nickel-plated zinc or a glass reinforced polymer that is consistent with the <br />material forming the associated lC connector body. The design mechanism for mounting the coupler to <br />the connector panel may be flanged or threaded but shall coincide with the connector panel punch-outs. <br />All coupler sleeves shall be ceramic of the split clamshell or clover leaf design. The temperature operating <br />range for couplers shall be the same as that specified for the SC connectors. <br />4.9 Pigtails <br />Pigtails shall be of simplex (one fiber) construction, in 900 µm tight-buffer form, surrounded by Aramid <br />for strength, with a connector on one end. The outer jacket shall be yellow PVC with a nominal diameter <br />of 3 mm, marked with the manufacturer’s identification information. All pigtails shall be of adequate <br />length for the intended connection purpose, but not less than two meters in length. Pigtails installed in <br />conduit shall follow the installation procedures outlined for fiber-optic cables, except that the pulling <br />tension shall not exceed 500 N (110 lbf.). <br />4.10 Fiber Termination Panels <br />Fiber terminations shall be housed in a rack mounted fiber termination panel, sized appropriately for the <br />cable size installed. All materials including fiber panel housing, pigtails, splice cassettes, trays, connector <br />panels and all other materials required for a complete working system shall be provided by the <br />Contractors and shall be included in Contractor pricing.