<br />THE CITY OF SUNNY ISLES BEACH <br />PROJECT NO. 21-1011 <br />BUILDING DEPARTMENT RELOCATION TO ANNEX <br /> <br />Project No. 21-1011 November 2024 033000 Cast-in-Place Concrete-15 <br /> <br /> <br />3. Correct localized low areas during or immediately after completing surface <br />finishing operations by cutting out low areas and replacing with patching <br />mortar. Finish repaired areas to blend into adjacent concrete. <br /> <br />4. Repair defective areas, except random cracks and single holes 1 inch or <br />less in diameter, by cutting out and replacing with fresh concrete. <br />Remove defective areas with clean, square cuts and expose steel <br />reinforcement with at least a 3/4-inch clearance all around. Dampen <br />concrete surfaces in contact with patching concrete and apply bonding <br />agent. Mix patching concrete of same materials and mixture as original <br />concrete except without coarse aggregate. Place, compact, and finish to <br />blend with adjacent finished concrete. Cure in same manner as adjacent <br />concrete. <br /> <br />5. Repair random cracks and single holes 1 inch or less in diameter with <br />patching mortar. Groove top of cracks and. cut out holes to sound concrete <br />and clean off dust, dirt, and loose particles. Dampen cleaned concrete <br />surfaces and apply bonding agent. Place patching mortar before bonding <br />agent has dried. Compact patching mortar and finish to match adjacent <br />concrete. Keep patched area continuously moist for at least 72 hours. <br /> <br />E. Perform structural repairs of concrete, subject to Engineer's approval, using <br />epoxy adhesive and patching mortar. <br /> <br />F. Repair materials and installation not specified above may be used, subject to <br />Engineer's approval. <br /> <br />3.8 PLANT QUALITY CONTROL <br /> <br />A. Sufficient testing shall be done by the supplier to assure the quality and <br />consistency of the mix produced. The field tests are not to be used as a gauge of <br />this quality. <br /> <br />3.9 FIELD QUALITY CONTROL <br /> <br />A. Provide under provisions of Division 1 - General Requirements. <br /> <br />B. Concrete Tests: Testing of composite samples of fresh concrete obtained <br />according to ASTM C 172 shall be performed according to the following <br />requirements: <br /> <br />1. Testing Frequency: Obtain one composite sample for each day's pour of each <br />concrete mixture exceeding 5 cu. yd., but less than 25 cu. yd., plus one set <br />for each additional 50 cu. yd. or fraction thereof. <br /> <br />a. When frequency of testing will provide fewer than five compressive- <br />strength tests for each concrete mixture, testing shall be conducted <br />from at least five randomly selected batches or from each batch if <br />fewer than five are used. <br /> <br />2. Slump: ASTM C 143; one test at point of delivery for each composite <br />sample, but not less than one test for each day's pour of each concrete <br />mixture. Perform additional tests when concrete consistency appears to