My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Attachment C - Biddding Specification 1-23-25
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(25-01-01) City Annex Building Construction Renovations
>
INVITATION TO BID 25-01-01 CITY ANNEX BUILDING CONSTRUCTION RENOVATIONS
>
Attachment C - Biddding Specification 1-23-25
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/20/2025 9:22:18 AM
Creation date
2/20/2025 9:18:50 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
City Annex Building Construction Renovations
Bid No. (xx-xx-xx)
25-01-01
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
960
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />THE CITY OF SUNNY ISLES BEACH <br />PROJECT NO. 21-1011 <br />BUILDING DEPARTMENT RELOCATION TO ANNEX <br /> <br />Project No. 21-1011 November 2024 033000 Cast-in-Place Concrete-17 <br /> <br /> <br /> <br />9. Additional Tests: Testing and inspecting agency shall make additional tests <br />of concrete when test results indicate that slump, air entrainment, <br />compressive strengths, or other requirements have not been met, as <br />directed by Engineer. <br /> <br />a. If compressive strength requirements are not met, steps shall be <br />taken to increase average of subsequent strength test results. <br />Engineer shall have right to order a change in proportions of mix for <br />remaining work. Engineer shall also have right to require conditions <br />of temperature and moisture necessary to secure required strength. <br /> <br />b. If any strength test of laboratory-cured cylinders falls below specified <br />compressive strength by more than 500 psi or if tests of field-cured <br />cylinders indicate deficiencies in protection or curing, steps shall be <br />taken to assure that the load-carrying capacity of structure is not <br />jeopardized. <br /> <br />c. If likelihood of low-strength concrete is confirmed and computations <br />indicate that load-carrying capacity may have been significantly <br />reduced, tests of cores drilled from area in question may be required in <br />accordance with ASTM C 42. In such cases, three cores shall be taken <br />for each strength test more than 500 psi below specified compressive <br />strength. If concrete in structure will be dry under service condition, <br />cores shall be air dried (temperature 60° to 80° F., relative humidity <br />less than 60%) for 7 days before test and shall be tested dry. If <br />concrete in structure will be more than superficially wet under service <br />conditions, cores shall be immersed in water for at least 40 hours and <br />be tested wet. <br /> <br />d. Concrete in an area represented by core tests shall be considered <br />structurally adequate if average of three cores is equal to at least 85% <br />of specified compressive strength and if no single core is less than 75% <br />of specified compressive strength. To check testing accuracy, locations <br />represented by erratic core strengths may be retested. <br /> <br />e. If criteria of paragraph (d) are not met, and if structural adequacy <br />remains in doubt, the Engineer may order load tests as outlined in ACI <br />318 for questionable portion of structure or require other appropriate <br />action. <br /> <br />f. All costs associated with performing analytical investigations, core <br />testing and load testing shall be paid for by Contractor. <br /> <br />10. Nondestructive Testing: Impact hammer, Sonoscope, or other nondestructive <br />device may be permitted by Engineer but will not be used as sole basis for <br />approval or rejection of concrete. <br /> <br />11. Additional testing and inspecting, at Contractor's expense, will be performed to <br />determine compliance of replaced or additional work with specified <br />requirements. <br /> <br />
The URL can be used to link to this page
Your browser does not support the video tag.