Laserfiche WebLink
Project No. 21-1011 November 2024 022840-3 <br />THE CITY OF SUNNY ISLES BEACH <br />PROJECT NO. 21-1011 <br />BUILDING DEPARTMENT RELOCATION TO ANNEX <br /> <br /> <br />3.2 APPLICATION <br /> <br />A. Notify Owner's laboratory 48 hours before preparing mixture of concentrate and water as <br />recommended by the manufacturer for the specific applications and conditions applying to the <br />project. <br /> <br />B. Apply treatment to the following: <br /> <br />1. Soil and earth which will be covered by or lie adjacent to new buildings. <br /> <br />2. Masonry foundations. <br /> <br />3. Areas around pipes and conduits penetrating slabs on fill to provide a lethal barrier <br />to subterranean termites. <br /> <br />C. Apply solution after subgrade has been made ready for placement of floor slab vapor barrier, <br />and as soon as practical prior to placement of concrete slabs and caps on masonry piers, but <br />after footings, foundation walls, and below grade waterproofing have been completed. <br /> <br />D. Make application at least l2 hours prior to placement of concrete slabs during normal working <br />hours in order to be subject to inspection. Notify applicator at least 24 hours prior to time <br />application of soil poisons will be completed. <br /> <br />E. Soil Conditions: Apply soil poisoning when moisture content soil is sufficiently low to allow <br />uniform distribution of chemical throughout specified areas. <br /> <br />F. Application Under Slabs on Fill or Grade: Apply solution uniformly to all areas under <br />concrete slabs, including walkways, entrance platforms and sidewalks within 5' of buildings. <br />Apply a minimum of 1 gallon of soil poison uniformly to each 10 sf of area to be treated. <br />Treat ground areas under concrete slabs on grade and paving which abut building slabs for <br />a distance not less than 3' from building. <br /> <br />G. Application Along Foundation Walls, Pipes, and Conduits: Treat critical areas along both <br />sides of exterior and interior foundation walls, columns, and around utility pipes, conduits, <br />ducts and other such items extending through soil beneath and adjacent to new construction, <br />to a depth of one foot in a strip 6" wide, at a rate of 4 gallons of soil poison to each 10 sf. <br />Mix chemical with soil as it is placed against walls and utility lines. Apply at least one gallon of <br />soil poison around each pipe. <br /> <br />H. Re-treatment of Disturbed Soil: Retreat soil surfaces that are disturbed after treatment and <br />before placement of slabs and covering structures. <br /> <br />3.3 CLEAN UP <br /> <br />A. Improper disposal of pesticide, spray mixture or Rinsate is a violation of Federal law. Comply <br />with manufacturer’s instructions for disposal of these material and empty containers. Do not <br />allow supplies of chemicals to remain on site unattended. <br /> <br /> <br />END OF SECTION