Zoning Resolution 26-Z-221
SIBFL
>
City Clerk
>
Resolutions
>
Zoning
>
2026
>
Zoning Resolution 26-Z-221
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/20/2026 3:48:38 PM
Creation date
3/17/2026 12:05:20 PM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Zoning Resolution
Resolution Number
26-Z-221
Date (mm/dd/yyyy)
02/19/2026
Description
Approving Site Plan Appl (PZ2025-08) MB RE Investments, LLC for "Miami Beach Club" (62) Story Residential Condo Tower w/ 524,212.8 Sq. Ft of FAR.
Reference
Needs to be resigned by Atty
Supplemental fields
Comment
Heard with Companinon Reso No.: 2026-3963; Item 9A.
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
334
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Kim <br />TCG 08/19/25 Response: This item is still pending future civil engineering submittal. <br />LSN Law, P.A. 09/10/25 Response: Noted, will be addressed at time of full building <br />permit submittal. <br />TCG 09/26/25 Response: Addressed. A condition of approval will be provided which <br />requires the applicant to provide at the time of full building permit submittal. <br />6. Civil Engineering Plan Sheets: C-400 <br />• Provide existing utility information to confirm connection point and <br />constructability. <br />• Provide a profile view of the proposed connection to confirm relation of the <br />proposed water main to the other utilities. <br />• Provide a meter for the irrigation and the fire service line <br />• Provide MEP plans showing the water and sewer lines coming out of the building <br />• Obtain fire department approval for the fire service locations and type of <br />connection. <br />• Missing callouts for items shown along the fire service line <br />• Missing callouts for pipe lengths <br />• Indicate proper names for the water service line components, including backflow <br />preventer assembly <br />• Update legend <br />• Organize notes to fit all of them in the sheet <br />• Per the Miami -Dade Code of Ordinances: Connection to meet the requirements <br />of the Florida Building Code and the Miami -Dade County Public Works Manual <br />• Provide a profile for the sanitary sewer lateral <br />• Please confirm how the sanitary sewer is connected to the existing sanitary <br />sewer system. <br />• Provide sanitary sewer pipe sizing calculations <br />• Provide calculations for the water main pipe sizing <br />LSN Law, P.A. 07/30/25 Response: Acknowledged. The information listed here will be <br />addressed once MEP coordination has commenced. <br />TCG 08/19/25 Response: This item is still pending future civil engineering submittal. <br />LSN Law, P.A. 09/10/25 Response: Noted, will be addressed at time of full building <br />permit submittal. <br />® CORRADINO.COM 40 <br />