Laserfiche WebLink
4. 265-35.D(4):Setbacks: <br /> ( Required Provided <br /> Front <br /> Tower 75 feet 105 feet 7 inches <br /> Complies. <br /> Pedestal 50 feet 131 feet 9 inches <br /> Complies. <br /> Pedestal 10 feet 50 feet 0 inches <br /> (Subterranean) Complies. <br /> Rear Bulkhead line or 20 feet from the 35 feet 0 inches <br /> rear property line, whichever is (Tower) Complies. <br /> closer to Collins Ave. Bulkhead line <br /> (Pedestal) Complies. <br /> Side North <br /> Tower 50 feet 50 feet. Complies. <br /> Pedestal Three-foot setback for each two 20 feet. Complies. <br /> feet of building height up to a <br /> maximum setback of 20 feet. <br /> Pedestal 0 feet 20 feet 0 inches. <br /> (Subterranean) Complies <br /> Side South <br /> Tower 50 feet 50 feet. Complies. <br /> Pedestal Three-foot setback for each two 20 feet 0 inches. <br /> feet of building height up to a Complies. <br /> maximum setback of 20 feet. <br /> Pedestal 0 feet 20 feet 0 inches. <br /> (Subterranean) Complies <br /> 5. 265-35. D (6) Maximum Building Width: Complies. <br /> Allowed: 250 feet. • <br /> Provided: 201 feet 2 inches. <br /> 6. 265-35.D (8) Beach Access Easement: Complies. <br /> Required: 20 feet wide and located within a required side yard setback. <br /> Provided: 20 feet wide and located within the south side yard setback area. <br /> 7. 265-35.D (9) Floor Area Ratio: Complies. <br /> Maximum floor area ratio (265-35.D(9)(b)): <br /> Permitted: Base 2.50 (339,282.5 square feet); with FAR Bonus and TDRs 5.98- <br /> (811,563.7 square feet). <br /> Provided: 5.98 with bonus FAR and TDRs — 811,560 square feet. <br /> 4 <br /> U:IPLANNING&ZONING20081ZONING HEARING-APPLICATIONSU015 APPLICATION\PZ20 15-06 Annani/CASA <br />