Laserfiche WebLink
Report of Geotechnical Exploration November 7, 2014 <br />Samson Oceanfront Park AREHNA Project B-14-124  <br /> <br /> <br />6 | Page <br />5.0 DESIGN RECOMMENDATIONS <br /> <br /> 5.1 General <br /> <br />Our geotechnical evaluation is based upon the previously presented project information as well as the field <br />data obtained during this geotechnical exploration. If final structure or foundation loads are significantly <br />different from those described or if the subsurface conditions during construction are different from those <br />revealed by our boring, we should be notified immediately so that we might review our recommendations <br />presented in this report. Our recommended site preparation is presented in Section 6.0, General Site <br />Preparation. <br /> <br />5.2 Auger Cast Piles <br /> <br />The proposed stage and playground roof structure should be constructed on 14-inch auger cast piles. We <br />recommend the piles be installed to a depth of 35 feet below the existing ground surface. An allowable axial <br />compression capacity of 35 kips and an allowable axial tension capacity of 20 kips can be used for design. <br /> <br />Installing auger cast piles requires equipment consisting of a mobile base carrier fitted with a hollow-stem <br />flight auger. The auger is drilled into the ground to the desired depth and then grout is pumped through <br />the auger as it is extracted. A continuous flow of fluid should be observed at the ground surface during <br />grouting. Reinforcement is placed after the pile is grouted. <br /> <br />We recommend a load test be performed on a non-production pile to evaluate the performance of the pile <br />installation equipment and to confirm the design allowable pile capacity. The test should be performed <br />on a non-production pile test loaded to a minimum of two times the allowable compressive design <br />capacity or to failure. Installation of production piles may proceed upon successful completion of the <br />load test. Installation should be monitored by a geotechnical engineer or engineering technician working <br />under the direction of a geotechnical engineer. <br /> <br />5.3 Settlement <br /> <br />Settlement of pile supported structural elements should be small and tolerable for a typical foundation <br />configuration. Based on the subsurface soil conditions encountered in the soil borings performed for this <br />report and our past experience with similar soil conditions, we do not anticipate significant downdrag <br />loads acting on the piles. <br /> <br />5.3 Floor Slab Design <br /> <br />It is expected that the floor slab of the stage will be supported on compacted existing soils or structural fill. If <br />site preparation is performed in accordance with the recommendations presented in this report, the modulus <br />of vertical subgrade reaction (k) for the slab bearing soils is expected to be on the order of 150 pounds per <br />square inch per inch of vertical deflection (pci). Our evaluation was based on satisfactory performance of our