My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Beiswenger - Structural
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
RFP
>
RFP No. 10-07-02 Fishing Pier
>
Specifications
>
Beiswenger - Structural
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/5/2010 10:29:44 AM
Creation date
11/4/2010 4:01:32 PM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Demolish Fishing Pier
Bid No. (xx-xx-xx)
10-07-02
Project Type (Bid, RFP, RFQ)
RFP
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
38
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />that have the capacity to store all QC, Verification, "hold" and Independent Verification <br />cylinders simultaneously for the initial curing. All cylinders will be clearly identified as outlined <br />in the Sample/Lot Numbering System instructions located on the State Materials Office website. <br />Deliver the QC samples, including the QC "hold" cylinder to the final curing facility in <br />accordance with ASTM C 31. At this same time, the Department will deliver the Verification <br />samples, including the Verification "hold" cylinder, to their final curing facility. <br />Test the QC laboratory cured samples for compressive strength at the age of 28 <br />days, or any other specified age, in a laboratory meeting and maintaining at all times the <br />qualification requirements listed in Section 105. <br />The QC testing laboratory will input the compressive strength test results into the <br />Department's sample tracking database within 24 hours. When the QC testing laboratory cannot <br />input the compressive strength test results into the Department's sample tracking database within <br />24 hours, the QC testing laboratory will notify the Verification testing laboratory within 24 hours <br />of testing the cylinder and provide the Verification testing laboratory the compressive strength <br />test results. Ensure the compressive strength results are input into the Department's sample <br />tracking database within 72 hours of determining the compressive strength of the cylinders. <br />The Department will average the QC compressive strength test data, average the <br />Verification compressive strength test data, and compare the averages. In the event that one set <br />of compressive strength data for a set of cylinders falls outside the range of the other set of <br />cylinders, use the lower Range of Average Compressive Strength to determine the comparison <br />criteria. Based on this comparison, the Department will determine if the Comparison Criteria as <br />shown in Table 7 has been met. When the difference between QC and Verification are less than <br />or equal to the Comparison Criteria, the QC data is verified. When the difference between QC <br />and Verification data exceeds the Comparison Criteria, the Engineer will initiate the resolution <br />procedure. <br /> <br />Table 7 <br />Range of Average Compressive Strength Comparison Criteria <br />Less than 3500 psi 420 psi <br />3,50 I - 4,500 psi 590 psi <br />4,50 I - 6,500 psi 910 psi <br />6,501 - 8,500 psi 1,275 psi <br />Greater than 8,500 psi 1,360 psi <br /> <br />SUBARTICLE 346-9.2 (Pages 334 - 335) is deleted and the following substituted: <br /> <br />346-9.2 Sampling Frequency: <br />As a minimum, sample and test concrete of each design mix for water to <br />cementitious materials ratio, air content, temperature, slump and compressive strength once per <br />LOT as defined by Table 8. When more than one concrete production facility is used for the <br />same mix design, describe the method of sampling, testing and LOT numbering in the QC Plan. <br />The Engineer will randomly verify one of every four consecutive LOTs of each design mix <br />based on a random number generator. The Department may perform Independent Verification <br />
The URL can be used to link to this page
Your browser does not support the video tag.