Laserfiche WebLink
<br />I <br />I <br /> <br />.~_~<~O~---~ <br />~-"1!f3~~~'hq2::~':1_(Camplete-ane Sectlan E far each key persa(0Jf~ ~ " ;j <br /> <br />15. FIRM NAME AND LOCATION (Cftyand State) <br />CES Consultants, Inc., Miami Lakes, FL (Laboratory Facility) <br />16. EDUCATION (DEGREE AND SPECIALlZA TlON) 17. CURRENT PROFESSIONAL REGISTRATION (STATE AND DISCIPLINE) <br />M.S., Industrial Engineering, Florida International University, <br />Miami, Florida <br />B.S., Mechanical Engineering, NED University of Engineering and <br />Technology, Karachi, Pakistan <br />18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.) <br />Mr. Uddin has over 9 years of engineering and materials testing experience working with federal, state and local <br />governments, where he coordinated testing and implementation of international standards specifications such as <br />outlined in ASTM, ACI, FAA, FOOT, CTQP standards to ensure regulatory compliance. Mr, Uddin is certified and <br />experienced in soil, concrete and asphalt inspection as per FOOT CTQP standards. He has successfully completed <br />projects in the areas of planning, permitting, construction, pavement, concrete, operations and maintenance, and an <br />array of other industrial engineering fields. <br /> <br /> <br />ineer <br /> <br />14. YEARS EXPERIENCE <br />a. TOTAL b. WITH CURRENT FIRM <br />15 2 <br /> <br />12. NAME <br />Aleem Uddin <br /> <br />19. RELEVANT PROJECTS <br /> <br /> (1) TITLE ANO LOCATION (City and State) (2) YEAR COMPLETED <br /> PTP Roadway Imwovements along NW 74th Street from NW 10th PROFESSIONAL SERVICES T CONSTRUCTION (If applicable) <br /> Avenue to NW 84 h Avenue, Miami, FL Ongoing <br />a. (3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE [ X] Check if project performed with current firm <br /> Mr. Uddin is currently providing materials testing services for this drainage and roadway project. The following are the tests <br /> that Mr. Uddin is performing: Laboratory California Bearing Ratio (CBR) per ASTM-1883, standard proctor per AASHTO T-99 <br /> and ASTM 0-698, modified per AASHTO T-180 and ASTM-1577, and Lime rock bearing ratio (LBR) per FOOT standards. <br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> Miami Dade Public Works Department, Miami, FL PROFESSIONAL SERVICES I CONSTRUCTION (If applicable) <br /> Varies <br />b. (3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE [ X] Check if project performed with current firm <br /> Mr. Uddin perfonns various laboratory testing duties on different projects for several of the departments in Miami-Dade <br /> County. Testing requests include: soils, asphalt, concrete, and borings. The Departments include water & sewer, transit, <br /> seaoort, aviation, & oublic works. <br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> Miami International Airport South Terminal Dual Taxiway, Miami, PROFESSIONAL SERVICES I CONSTRUCTION (If applicable) <br /> FL Ongoing <br /> (3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE I X] Check if project performed with current firm <br />C. Mr. Uddin is currently providing soils, foundations and material testing services on this project. He perfonns site visits, <br /> inspections, meetings, coordination with all stake holders and supervision of all material testing as requested by the client. The <br /> testing services include but are not limited to field and laboratory CBR tests, compaction test by sand cone method, proctor <br /> and gradation for soils, steel inspection for underground structures at the concrete plant and others as per ASTM, ACI, and <br /> CTOP standards. <br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> Herbert Hoover Dike Rehabilitation, Reach I, US Army Corp of PROFESSIONAL SERVICES 1 CONSTRUCTION (If applicable) <br /> Engineers, Lake Okeechobee, FL Ongoing <br />d. (3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE [ X ] Check if project performed with current firm <br />As a certified quality control laboratory for the US Army Corp of Engineers, Mr. Uddin is supervising and perfonning laboratory <br /> testing on a/A samples (soil cement bentonite). This testing includes unconfined compressive strength as per ASTM 0-2166 <br /> and permeability tests as per ASTM 0-5084. Several field visits are required to check and evaluate the performance of the <br /> Contractor field labs. <br /> (1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED <br /> Miami International Airport Mover APM System, Miami, FL PROFESSIONAL SERVICES I CONSTRUCTION (If applicable) <br /> N/A <br /> (3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE [X ] Check if project performed with current firm <br />e. Mr. Uddin is currently providing construction materials testing and inspection services on the base and sub-grade, cast-in- <br /> place concrete. CES is monitoring construction materials and construction methods for compliance with the contract <br /> documents. CES is perfonning the following tests: Backfill monitoring, compaction tests, standard proctor tests per AASHTO <br /> T-99 and ASTM 0-698, modified proctor tests per AASHTO T-180 and ASTM-1577, concrete laboratory tests per ASTM C-31 , <br /> strenQth tests per C-39 usinQ C-617 or C-1231 <br /> <br />STANDARD FORM 330 (1V2004) PAGE 1 <br />