<br />(3) BRIEF DESCRIPTION AND SPECIFIC ROLE <br /> <br />[2J Check if project perfonned with current firm <br /> <br />Repair and corrosion protection of the S-21 Structure, as follows: <br /> <br />. Installation of a passive corrosion protection system for the upstream steel sheet pile wing walls, <br />. Installation of an active corrosion protection system for the S-21 superstructure (above mean water level), <br />. Repair of the concrete Service Platform. This work will include identification of areas of existing concrete <br />to be removed and replaced, the repair or replacement of reinforcing bars, and the repair of cracks in the <br />concrete, based on the corrosion survey. <br />. Replacement of the existing access hatches in the Service Platform with stainless steel access hatches. <br />. Addition of three (3) new 36" x 36" stainless steel hatches in the Service Platform, if shown by analysis to <br />be structurally feasible, <br />. Replacement of the steel angle at the bottom edge of the Service Platform with a stainless steel angle. <br />. Replacement of the Service Platform chain link fence post embedments with stainless steel post <br />embedments, <br />. In-kind replacement of the Service Platform chain link fence with a new galvanized steel chain link fence, <br />. Repair of the concrete Operating Platform, This work will include identification of areas of existing <br />concrete to be removed and replaced, the repair or replacement of reinforcing bars, and the repair of cracks <br />in concrete, based on the corrosion survey, <br />. Replacement of the work lights on the Operating Platform, <br />. Repair of miscellaneous concrete cracks and spalls in the superstructure, <br /> <br />Review the existing control building to withstand wind and wave forces from a 200-year storm. The building floor <br />is below the expected surge flood elevation for this site, and is vulnerable to these forces. Consultant will <br />prepare a brief letter report describing the strength of the building to resist wind and wave forces, supported by <br />calculations. <br /> <br />Mr. Travis' role was to develop and implement project quality processes for this project, and monitor the project to ensure <br />all processes are adhered to, and are effective. <br /> <br />1) TITLE AND LOCATION (City and State) <br />Quality Manager, Boca Raton I Regional Quality leader <br /> <br />(2) YEAR COMPLETED <br /> <br />PROFESSIONAL CONSTRUCTION(if <br />SERVICES: applicable): <br /> <br />[2J Check if project performed with current firm <br /> <br />(3) BRIEF DESCRIPTION AND SPECIFIC ROLE <br />c. Role. <br /> <br />Responsible for ensuring that all activities associated with this project comply with URS, Boca Raton <br />Quality Policies and Procedures <br /> <br />URS <br /> <br />3 <br />