My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(06-06-02) Alley Way Improvements
>
Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/13/2012 4:06:34 AM
Creation date
1/20/2011 3:56:07 PM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Alley Way Improvments
Bid No. (xx-xx-xx)
06-06-02
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
202
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F <br />J. The entrained air, as measured by the Pressure Method, ASTM C231, shall <br />be as shown in (Table C). <br />TABLE C <br />Nominal Maximum Size <br />of Coarse Aggregate(in) <br />2'f <br />1" <br />3/4" <br />1.07 ACCEPTANCE TESTS <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />1 <br />a,os <br />Total Air Measured at <br />Discharge from truck ( %) <br />2.5-5.5 <br />6.5 <br />4.0-8.0 <br />A. Conformity of aggregates to these Specification, and the actual proportions <br />of cement, aggregates, and water necessary to produce concrete <br />conforming to the requirements set forth in Table A, shall be determined by <br />tests made with representative samples of the materials to be used on the <br />work. Tests will be made by an accredited testing laboratory, and approved <br />by the Engineer. <br />B. Cement may be subject to testing to determine that it conforms to the <br />requirements of this Specification. Methods of testing shall conform to the <br />appropriate specification, but the place, time, frequency and method of <br />sampling will be determined by the Engineer in accordance with the <br />particular need. <br />C. Water content of the concrete shall be based on a curve showing the <br />relation between water content and 7 and 28 -day compressive strengths of <br />concrete made using the proposed materials. The curves shall be <br />determined by four or more points, each representing an average value of <br />at least three test specimens at each age, and shall have a range of values <br />sufficient to yield the desired data, including all the compressive strengths <br />called for on the Drawings, without extrapolation. The water content of the <br />concrete to be used, as determined from the curve, shall correspond to the <br />test strengths of the laboratory trial mixtures as shown on (Table D) below. <br />* May be employed by preliminary design. <br />** To be used for final designs. <br />E. In no case, however, shall the resulting mix conflict with the limiting values <br />for maximum water - cement ratios and minimum cement contents as <br />specified in Table A. <br />03300 -4 <br />03- 4138.0 <br />TABLE D <br />Design <br />Min. Lab. <br />Strength <br />Strength <br />7 Days* <br />28 Days ** <br />3000 <br />2500 <br />3500 <br />3500 <br />3000 <br />4100 <br />4000 <br />3500 <br />4600 <br />* May be employed by preliminary design. <br />** To be used for final designs. <br />E. In no case, however, shall the resulting mix conflict with the limiting values <br />for maximum water - cement ratios and minimum cement contents as <br />specified in Table A. <br />03300 -4 <br />03- 4138.0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.