Laserfiche WebLink
<br />,..., <br /> <br />. <br /> <br />-, <br />. <br /> <br />Class 5 finish may be applied to attain a uniform appearance for the entire structure, to the <br />satisfaction of the Engineer. <br /> <br />., <br />. <br /> <br />, <br />. <br /> <br />548-5 Handling Storage and Shipping. <br />Handle, store and ship all components in a manner that prevents chipping, cracks, <br />fractures, excessive bending stresses, mud, dirt and debris. Support precast components in <br />storage on firm blocking located immediately adjacent to the attachment device. <br /> <br />M <br /> <br />548-6 Construction Requirements. <br />548-6.1 General: Due to the unique nature of the structure and concept, procure <br />from the Wall Supplier fully detailed shop drawings, technical instructions, guidance in <br />preconstruction activities and on-site technical assistance during construction. Closely <br />follow any instructions from the Wall Supplier, unless otherwise directed by the Engineer. <br />Submit a copy of any instructions from the Wall Supplier to the Engineer. Verify all <br />pertinent retaining wall information (soil parameters, wall alignment, utility locations, <br />conflicting structures) prior to the Wall Supplier finalizing shop drawings. Bring any <br />conflicts not shown in the Contract Documents to the Engineer's attention. <br />548-6.2 Wall Excavation: Excavate to the limits shown in the Contract Documents <br />and in conformance with Section 1 25. <br />548-6.3 Foundation Preparation: Grade the foundation for the structure level for a <br />width equal to or exceeding the limits of the retaining wall volume or as shown in the <br />Contract Documents. Prepare the foundation in conformance with Section 125. <br />In addition to the compaction requirements of Section 125, compact the <br />graded area with an appropriate vibratory roller weighing a minimum of 8 tons [7 metric <br />tons] for at least five passes or as directed by the Department's District Geotechnical <br />Engineer. Remove and replace any soft or loose foundation subsoils which, are incapable of <br />sustaining the required compaction to the Engineer's satisfaction. <br />For permanent MSE wall systems, provide an unreinforced concrete leveling <br />pad as shown in the Contract Documents. Cure the leveling pad a minimum of 12 hours <br />before placement of precast wall components. <br />548-6.4 Wall Erection: Assemble, connect and support wall components as <br />recommended by the Wall Supplier. As backfill material is placed behind the wall face, <br />maintain the wall in the vertical position or slightly battered into the backfill to provide a <br />final vertical alignment (by means of bracing, temporary wooden wedges placed in the joint <br />at the junction of the two adjacent precast components on the external side of the wall or <br />other alignment aids). Remove wooden wedges as soon as the precast component above <br />the wedged precast component is completely erected and backfilled. External bracing is <br />required for the initial lift of MSE systems. <br />Place soil reinforcement normal to the face of the wall, unless otherwise <br />shown in the Contract Documents or directed by the Engineer. Prior to placement of the <br />reinforcement, compact the backfill in accordance with 548-6.5. <br />548-6.4.1 Tolerances for Permanent Walls: Ensure that vertical tolerances <br />(plumbness) and horizontal alignment tolerances do not exceed 3/4 inch [20 mm] when <br />measured with a 10 foot [3.048 m] straight edge. The maximum allowable offset in the <br />joint between precast components is 3/4 inch [20 mm]. The final overall vertical tolerance <br />of the completed wall (plumbness from top to bottom) shall not exceed 1/2 inch per <br />10 feet [5 mm per meter] of wall height. Horizontal and vertical joints between precast <br />components shall not be less than 1/2 inch [13 mm] or more than 1 1/4 inch [30 mm]. <br /> <br />" <br />. <br /> <br />, <br />. <br /> <br />.., <br />. <br /> <br />.., <br />. <br /> <br />r"1 <br />. <br /> <br />.., <br />. <br /> <br />,., <br />. <br /> <br />. <br /> <br />...., <br /> <br />. <br /> <br />..., <br /> <br />. <br /> <br />.., <br /> <br />. <br /> <br />-, <br /> <br />. <br /> <br />r-, <br /> <br />. <br /> <br />1"'"1 <br /> <br />. <br /> <br />......, <br /> <br />09/09 <br /> <br />01000-125 <br /> <br />03-4122.F <br /> <br />- <br />