My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications Vol. II
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(09-09-01) Streetscape Improvements 175th Ter & 183rd St
>
Specifications Vol. II
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2011 11:13:16 AM
Creation date
5/12/2011 11:12:16 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Median Closure
Bid No. (xx-xx-xx)
09-09-01
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />" <br /> <br />. <br /> <br />.., <br /> <br />.., <br />. <br /> <br />carbonate material as determined by FM 5-510 and the Engineer grants approval of the <br />source prior to its use. As an exception, mixes that contain a minimum of 60% crushed <br />granite may contain up to 40% fine aggregate from other approved sources. <br />337-3.2.2.2: Asphalt Binder: Use an ARB-5 asphalt rubber binder. If <br />called for in the Contract, use a PG 76-22 asphalt binder. <br />337-3.3 Grading Requirements: <br />337-3.3.1 FC-5: Use a mixture having a gradation at design within the <br />ranges shown in Table 337-1. <br /> <br />. <br /> <br />.., <br /> <br />. <br /> <br />., <br />. <br /> <br />Table 337-1 <br />FC-5 Gradation Design Range <br />3/4 inch 1/2 inch 3/8 inch No. 4No.8 No. 16 No. 30 No. 50 No. 100 No. 200 <br />[19.0 [12.50 [9.50 [4.75 [2.36 [1.18 [600 :m] [300 :m] [150 :m] [75 :m] <br />mm] mm] mm] mm] mm] mm] <br />100 85-100 55-75 15-25 5-10 -- -- n -- 2-4 <br /> <br />.., <br />. <br /> <br />,.., <br />. <br /> <br />1"1 <br />. <br /> <br />337-3.3.2 FC-9.5: Meet the design gradation requirements for a SP-9.5 <br />Superpave fine mix as defined in 334-3.2.2. <br />337-3.3.3 FC-12.5: Meet the design gradation requirements for a SP-12.5 <br />Superpave fine mix as defined in 334-3.2.2. <br /> <br />'1 <br />. <br /> <br />..., <br />. <br /> <br />337 -4 Mix Design. <br />337-4.1 FC-5: The Department will design the FC-5 mixtures. Furnish the materials <br />and all appropriate information (source, gradation, etc.) as specified in 334-3.2.7. The <br />Department will have two weeks to design the mix. <br />The Department will establish the design binder content for FC-5 within the <br />following ranges based on aggregate type: <br /> <br />1'"1 <br />. <br /> <br />,., <br />. <br /> <br />Aggregate Type Binder Content <br />Crushed Granite 5.5 - 7.0 <br />Crushed Limestone (Oolitic) 6.5 - 8.0 <br /> <br />. <br /> <br />337-4.2 FC-9.5 and FC-12.5: Provide a mix design conforming to the requirements <br />of 334-3.2 for Traffic Level C unless otherwise designated in the plans. Develop the mix <br />design using an ARB-5 or PG 76-22 asphalt binder if called for in the Contract Documents. <br />337-4.3 Revision of Mix Design: For FC-5, FC-9.5 and FC-12.5, meet the <br />requirements of 334-3.3. For FC-5, all revisions must fall within the gradation limits <br />defined in Table 337-1. <br /> <br />.., <br /> <br />,., <br />. <br /> <br />.., <br />. <br /> <br />,..., <br /> <br />337-5 Contractor's Process Control. <br />Provide the necessary process control of the friction course mix and construction in <br />accordance with the applicable provisions of 330-2 and 334-4 for FC-5, and 330-2 and <br />334-4 for FC-9.5 and FC-12.5. <br />The Engineer will monitor the spread rate periodically to ensure uniform thickness. <br />Provide quality control procedures for daily monitoring and control of spread rate <br />variability. If the spread rate varies by more than 5% of the spread rate set by the Engineer <br />in accordance with 337-9, immediately make all corrections necessary to bring the spread <br />rate into the acceptable range. <br /> <br />..., <br />. <br /> <br />,.., <br /> <br />. <br /> <br />. <br /> <br />.., <br /> <br />09/09 <br /> <br />01000-74 <br /> <br />03-4122.F <br /> <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.