Laserfiche WebLink
<br />~ <br /> <br />. <br /> <br />.., <br />. maximum time limit between the batching and when the concrete of each batch is <br />deposited during the production. <br />-, Upon the review and verification of the laboratory trial batch, <br />. field demonstration test data, inspection reports and contractor's certification statement, <br />the Department will approve the proposed mix design. <br />,., The Department may approve proposed flowing concrete <br />. mixes, centrally mixed at the placement site, without the production of demonstration <br />batches, provided that the proposed mix meets the following two criteria: <br />,., (1) A previously approved flowing concrete mix of the same <br />. class has demonstrated satisfactory performance under the proposed job placing conditions <br />with a minimum of fifteen consecutive Department acceptance tests, which met all plastic <br />,..., and hardened concrete test requirements. <br />. (2) The cementitious materials and chemical admixtures, <br />including the flowing concrete HRWR admixture, used in the proposed mix are the same <br />,.., materials from the same source used in the previously approved mix, (1) above, and the <br />. other materials and mix proportions are approved as similar by the Department. <br />Do not produce or place concrete until the design mixes have <br />.., been approved. <br />. 346-2.5.4 Corrosion Inhibitor Admixture: Use only with concrete containing <br />Type II cement, Class F fly ash or slag, and a water reducing retardant admixture, Type D, <br />r"1 or High Range Water Reducer admixture, Type G, to normalize the setting time of <br />. concrete. Ensure that all admixtures are compatible with the corrosion inhibitor admixture. <br /> <br />,..., 346-3 Classification, Strength, Slump and Air Content. <br />I 346-3.1 General: The separate classifications of concrete covered by this Section <br />are designated as Class I, Class II, Class III, Class IV, Class V and Class VI. Strength, <br />.., slump, and air content of each class are specified in Table 2: <br /> <br />. <br /> <br />,.., <br /> <br />TABLE 2 <br /> Specified Minimum Target Slump Air Content Range <br />Class of Concrete Strength (28-day) (psi) <br /> [(MPa)] (inches) [(mm)](c) (e) (%) <br />STRUCTURAL CONCRETE <br />I (Pavement) 3,000 [21] 2 [50] 1 to 6 <br />I (Special) (a) 3,000[21] 3 [75] (b) 1 to 6 <br />II (a) 3,400 [23] 3 [75] (b) 1 to 6 <br />II (Bridge Deck) 4,500[31] 3 [75] (b) 1 to 6 <br />III 5,000 [35] 3 [75] (b) 1 to 6 <br />III (Seal) 3,000 [21] 8 [200] 1 to 6 <br />IV 5,500 [38] 3 [75] (b) 1 to 6 <br />IV (Drilled Shaft) 4,000 [28] 8 [200] o to 6 <br />V (Special) 6,000 [41] 3 [75] (b) (d) 1 to 5 <br />V 6,500 [45] 3 [75] (b) (d) 1 to 5 <br />VI 8,500 [59] 3 [75] (b) (d) 1 to 5 <br /> <br />. <br /> <br />,.., <br /> <br />. <br /> <br />~ <br />. <br /> <br />,..., <br />. <br /> <br />.., <br />. <br /> <br />,., <br /> <br />. <br /> <br />" <br />. <br /> <br />M <br /> <br />09/09 <br /> <br />01000-92 <br /> <br />03-4122.F <br /> <br />. <br />