SUNNY ISLES BEACH PIER & RESTAURANT REVISIONS <br />SCOPE OF SERVICES - A'f- TACHN4lKK1 "A` <br />PLAN REVISION RELATED <br />TO: <br />MDFD —SITE PLAN REVIEW <br />Locate Hydrants on site plans, <br />mark as exist or new. <br />Locate Fire Depanment <br />corimmilon at least40'from <br />structuris <br />Hydrant to be located with 150' <br />of FD correction. <br />MDFD —UFE SAFEST' PLAN <br />COMMEN75 <br />Provide occupant bads per FFPC <br />101 -Table 7.3.17. sheets Al.1 & <br />A1.2 <br />Provide UfeSafety plans from all <br />level with: <br />Capacity OfExin. <br />Occupant load directed be <br />each 'L. <br />Occupant load of earh yarn. <br />Travel Disbnre to exits. <br />Out V a <br />Uffe Sbrety Systems <br />Dead ends & Common Path of <br />bravaildistaincle. <br />Erers comply With 1/2 the <br />diagonal dr.sace required for <br />famousness; Cemplywith 101• <br />7 5.1.3.1 <br />All exits shall terminate <br />directly at a public way, Sect 101. <br />7.7.1 FFPC. Problem @ Sheet A- <br />105 <br />Provide Restaurant Sewing <br />Plan per SDI - 121-563 <br />Provide Min. Ahle width pei <br />FFPC 101- 12.7.5.6.1.1 <br />Janitor closet requires <br />SNr.walls, 314 Hr. door with <br />closet FFPC 301.123.2.1 <br />For o nstrucbon type <br />lanhztion see FFPC 101 -Table <br />121.6 Problem ®Sheet A-M <br />np55gREfWA.AWX.' RodsM. Jf <br />a.lr' tr ivpx'naL ihw if <br />milpf "pil yetl0,t *If. ixJ <br />"raact. <br />CLIENT E UEST <br />HVAC system to remain. Reside <br />per load reduction. <br />Remold arcoustical ceiling and <br />and. <br />Redesign HVAC ducts & venh as <br />re ueed. <br />Atld Mb to paint caging, ducts, <br />owMUinflat black. <br />Add rough4n for 6 ceding fans <br />Modffy plans to show only 1 <br />double door on North. <br />All windows except bafta baths <br />to be horizontal rollers with sill <br />III approx . 42 -AFF. <br />Belswenger, Hach & Associates, Inc. <br />Date: 10 /4/2011 <br />