2. The gasket shall be a flush-seal type. <br /> <br />C. Pipe wall thickness for ductile iron pipe shall be in accordance with AWWA <br />C606. <br /> <br />2.08 FLANGED ADAPTERS <br /> <br />A. Flanged adapters for ductile iron piping shall have either steel or gray iron <br />bodies; models 912 or 913 as manufactured by Rockwell Industries, Styles 127 <br />and 128 by Dresser Ind., Clow or equal. <br /> <br />B. Flange adapters shall have a minimum rated working pressure of 175 psig for <br />gray iron body types and 150 psig for steel body types, and shall conform to <br />applicable requirements of AWWA/ANSI C115/A21.15 and AWWA/ANSI <br />C111/A21.11. <br /> <br />1. Bolt hole and bolt patterns shall conform to the mating flange patterns as <br />specified in the piping paragraphs. <br /> <br />2. Bolts, nuts and flange gaskets shall conform to the specifications for the <br />adjacent piping. <br /> <br />C. Pipe shall be anchored by using anchor studs drilled into the coupling and <br />connected pipe for nominal pipe sizes to twelve (12) inches. <br /> <br />1. For nominal pipe sizes above twelve (12) inches, pipe shall be restrained by <br />harnesses. <br /> <br />2.09 WALL SLEEVES, PIPES, AND CASTINGS <br /> <br />A. Wall pipes or wall sleeves shall be provided in accordance with the following <br />schedule, except where otherwise noted, when passing through new concrete <br />or masonry structures: <br /> <br />From To Fitting <br />Dry Interior Dry Interior Wall Sleeve with <br />Penetration Seal <br />Dry Interior Dry Exterior Wall Pipe <br />Dry Interior Wet Tank Wall Pipe <br />Dry Interior Earth Exterior Wall Pipe <br />Wet Tank Earth Exterior Wall Pipe <br />Wet Tank Wet Tank Wall Pipe <br />Wet Tank Dry Exterior Wall Pipe <br /> <br />B. Transitions between interior piping materials and yard piping materials that <br />occur in the structural walls shall be furnished in accordance with the details <br /> <br />City of Sunny Isles Beach <br />NE 174th Street Roadway Improvements <br />15105 - 12 Pipes and Tubes <br />14-1758 / 09-19-2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.