Il
<br /> PERKINS +WILL
<br /> 01. OUR PHILOSOPHY / Project Organization
<br /> v + S f ri rar _
<br /> ,',''j, '-''-'.:s;':',:':'\:::''!-.::.I'''. Nt tf ca
<br /> 111
<br /> x 8�,# , ,r'' za ,.......,,A,,..;: , f fid , `'
<br /> .. . . „. . i.„„,
<br /> u a.yn
<br /> iii
<br /> r ,,�
<br /> -
<br /> . .a"
<br /> "-
<br /> mom,
<br /> ;S::j. V:"' ;I N3 14i4 'YZ } 4
<br /> $ P �
<br /> i y . f'.-",4,1'$4 � t' r1rzar1,',,`,.,P,,'",'41..,*, 4" s ' *', , f I,t
<br /> -S •a F .. :. $ � . ° .1rs 'yk .n - ?s c ', N"& a f ,$i ,,......:';ii,*'
<br /> k ... � Z £ ya - Vim
<br /> .
<br /> ' y a w t4 p nom, t x,..,R., ,
<br /> Ill
<br /> '`x:77:7-4,7777:17?---:
<br /> , ,'.-,tib : » o-h, `v r' e r 4-a J £ .E iP.-..,,,,,t:-/i.:
<br /> ^r ti*-Y; s s n a '! °
<br /> °'+ �. >.. `1- x%'71,.':4,7 A :-&'r j by .' is .,,4,
<br /> ..T - �{ k £ L 1;e C.h ,yew
<br /> III
<br /> WORKING IN AN EXISTING BUILDING KNOWLEDGE OF SITE + EXISITING CONDITIONS
<br /> The most successful workplace and community civic space Perkins+Will has an extensive and ongoing working IN
<br /> solutions are those that relate to and are enhanced by relationship with the City of Sunny Isles Beach, having
<br /> integration with the base building architecture. For new completed design services for the Sunny Isles Government
<br /> interior construction within an existing building, we take Center Annex project. Additionally, both Larry Kline, IN
<br /> into account factors such as column spacing, window Managing Principal, and Carlos Vilato, Project Architect,
<br /> modules, convector conditions, core-to-perimeter circulation collaborated with the City of Sunny Isles Beach in the
<br /> 111
<br /> paths, as well as direct access to daylight as influential to completion of the first phase of the Government Center
<br /> interior planning. Other practical considerations include the (while at another firm). Perkins+Will is uniquely qualified
<br /> location of main trunk feeds&distribution paths, structural for this project due to our in-depth understanding of
<br /> 1111
<br /> framing/reinforcing, sizing of existing electrical panels, the Government Center site. We studied the site as part
<br /> floor trenching and/or coring, access to core closets, ADA of our design process during the design process for the
<br /> compliance of core bathrooms, fire suppression equipment, Government Center Annex. Members of the design teamIN
<br /> as well as the availability of supplemental cooling systems. from that project will bring their knowledge to this project.
<br /> The most significant risks associated with work in an Additionally, our team is familiar with Gateway Park and the
<br /> existing building relate to two things: unforeseen field recent success it has brought the City. We are excited at the 111
<br /> conditions(incurring cost and schedule impacts) and prospect of helping to complete the transformation into a
<br /> possible interruption of business. To mitigate these risks, true community destination.
<br /> III
<br /> our team conducts a detailed visual observation of the as-
<br /> built field conditions, along with the engineering consultant DEFINING THE SCOPE
<br /> and contractor for the project. By working in unison as At the onset of any project, it is essential that primary
<br /> IN
<br /> a team, potential conflicts are identified and alternate vision, goals and objectives for the work are understood
<br /> solutions are proactively identified before problems arise. and shared by all team members. At the earliest stages of
<br /> the project, Perkins+Will will work alongside the City toIII
<br /> articulate the long-term vision for this project. Together,
<br /> we will define the ways in which the architectural and
<br /> 1111
<br /> 10 Sunny Isles Government Center Lobby+Gateway Park Build-Out
<br />
|