Laserfiche WebLink
o� ]t 7L.,11`111 <br /> SYSTEMS <br /> The B1ueTOAD devices will be delivered and staged at an Econolite facility located in Miami-Dade <br /> County. The BIueTOAD Devices will be tagged and entered for asset tracking. <br /> Basis of Payment <br /> BIueTOAD devices will be-measured per each, and paid for upon proof of delivery of the BIueTOAD <br /> field devices to the Contractor facility. <br /> Task 6 Preventive Maintenance <br /> Description of Work <br /> Econolite will perform Preventive Maintenance for each traffic signal location. The work shall include the <br /> following activities: <br /> o Display Equipment Inspection <br /> • Visually inspect signal and pedestrian displays and verify all indications are operational, note <br /> condition and alignment of all heads, note any deficiencies <br /> o Detector Verification <br /> • Verify proper operation of vehicle detectors, note any faults and reset <br /> • Inspect condition of all loops and lead-ins; note sealant failures by street approach, lane and <br /> phase <br /> • Verify proper operation of pedestrian pushbuttons on all approaches, note failures or other <br /> issues <br /> • Check push button lamps, audio operation and direction, if applicable <br /> o Intersection Infrastructure Inspection <br /> • Check condition of pull-boxes; note size and number of any broken or missing lids, crushed <br /> boxes and buried boxes <br /> • Perform ground-level visual inspection of metal poles for damage,rust, cracked welds, <br /> grounding & foundation damage <br /> • Perform ground-level visual inspection of hand hole covers on steel poles; secure if necessary <br /> and note if missing <br /> • Perform ground-level visual inspection of conduit risers; note any repairs needed <br /> o Cabinet Inspection <br /> • Inspect foundation and exterior for damage and vandalism <br /> • Check door gaskets, anchor bolts,base extension bolts; reseal base if water is present <br /> • Check for signal plans; verify signal heads are per plan; note any discrepancies <br /> • Check/test interior cabinet lamps, fan and thermostat; replace any that are not working <br /> properly and note replacements <br /> • Check physical condition of meter/service disconnect, line filter and surge arrestor <br /> • Ensure all load switches and flashers have a tight and secure fit into the socket <br /> • Check for and note any burned, pitted, corroded or discolored contacts and terminals <br /> • Visually inspect condition of all relays and note if burned or full of ants; replace if necessary <br /> • Ensure all terminal connections and harnesses have a tight and secure fit; check for frayed <br /> writing and note if any are found <br /> • Visually check condition of all loading resistors <br /> 1250 N.Tustin Avenue 0 Anaheim,California 92807 0 Ph:(714)238-9277 0 Fax:(714)630-1973 <br /> econolite.com 0 feedback.econolite.com <br />