My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(08-06-01) Atlantic Isle Roadway and Utility Improvements
>
Specifications
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/21/2013 5:26:14 PM
Creation date
3/21/2013 5:25:32 PM
Metadata
Fields
Template:
CityClerk-Special Master Hrg.
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
235
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I <br /> 1 <br /> 3.09 REMOVAL OF FORMS <br /> A. Except as otherwise specifically authorized by the Engineer, forms shall not be <br /> removed before the concrete has cured as specified above in subparagraph 3.08C <br /> 1 and the concrete has attained a strength of at least 30 percent of the ultimate <br /> strength prescribed by the design, and not before reaching the following number of <br /> day-degrees (whichever is the longer): <br /> Forms for Day-Degree* <br /> Beams and slabs 500 <br /> 1 Walls and vertical surfaces (non-water retaining) 100 <br /> Walls and vertical surfaces (water retaining) 150 <br /> *Day-degree: Total number of days times average daily air temperature at surface <br /> of concrete. For example, 5 days at a daily weighted average temperature of 60 <br /> degrees F equal 300 day-degrees. Temperatures below 50 degrees F not to be <br /> included. <br /> 1 B. Shores shall not be removed until the concrete has attained at least 60% of the <br /> specified strength and also sufficient strength to support safely its own weight and <br /> the construction live loads upon it, but concrete shall be minimum age of 14 days <br /> before such removal. <br /> 3.10 FAILURE TO MEET REQUIREMENTS <br /> A. Should the strengths shown by the test specimens made and tested in accordance <br /> with the above provision fall below the values given in Table A, the Engineer shall <br /> have the right to require changes in proportions as outlined above to apply to the <br /> remainder of the work. Furthermore, the Engineer shall have the right to require <br /> additional curing on those portions of the structure represented by the test <br /> specimens which failed, the cost of such additional curing to be at the Contractor's <br /> expense. In the event that such additional curing does not give the strength <br /> required, as evidenced by core and/or load tests, the Engineer shall have the right <br /> to require strengthening or replacement of those portions of the structure which fail <br /> to develop the required strength. The cost of all such core borings and/or load <br /> tests and any strengthening or concrete replacement required because strengths <br /> of test specimens are below that specified, shall be entirely at the expense of the <br /> Contractor. In such cases of failure to meet strength requirements the Contractor <br /> t and Engineer shall confer to determine the adjustment, if any, can be made in <br /> conformity with Sections 16 and 17 of ASTM Specification C94 for Ready-Mixed <br /> Concrete. <br /> B. When the tests on control specimens of concrete fall below the required strength, <br /> the Engineer will permit check tests for structure in accordance with ASTM <br /> Methods C42 and C39. In case of failure of the latter, the Engineer, in addition to <br /> other recourses, may require, at the Contractor's expense, load tests on any one of <br /> the slabs, beams, and columns in which such concrete was used. Test need not <br /> be made until concrete has aged 60 days. <br /> 1 C. Slabs or beams, under load test, shall be loaded with their own weights plus a <br /> super-imposed load of 2 times design live load. The load shall be applied <br /> uniformly over portion being tested in approved manner, and left in position for 24 <br /> 05/08 03300-11 05-4893 <br />