Laserfiche WebLink
E-31Proven solutionsResponsive and dependable performance <br />City of Sunny Isles Beach RFQ No. 20-07-01: Continuing Professional Consulting Services (CCNA) <br />E. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />MDWASD Ocean Outfall Legislation Program, Miami-Dade County, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2017 2017 <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Project Engineer for development of a Conceptual Design Report for the projects in the North District transmission and <br />pumping system necessary to meet the requirements of the Ocean Outfall Legislation (OOL) Compliance Plan. This CDR <br />included approximately 21,000 LF of 48-inch diameter force main and approximately 1,500 LF of 36-inch diameter force <br />main. Tasks completed include Data Review and Pipeline Project Analysis. Size: 22,500 LF of Sanitary Sewer Force Mains <br />Cost: $250k <br />F. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />D/B Replacement of Water Main & Service Conversions in “Donut Hole” <br />Area, Miami Gardens, FL <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2019 Ongoing <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Project Engineer for the replacement of the undersized and deteriorated water mains and existing main loop closures. The <br />project includes the following main elements: ±22,450 LF of 8-inch ductile iron water main and pipe fittings: ±12,060 LF of <br />12-inch ductile iron water main pipe and fittings; ±1,050 LF of 6-inch ductile iron water main pipe and fittings; and ±560 <br />water service conversions from rear of property to front of property, requiring right-of-way and private property permitting. <br />G. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />MDWASD Engineering, Design and Related Services for the Local Pump <br />Station Improvement Program, Miami-Dade County, FL <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />Ongoing Ongoing <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Project Engineer providing inspection/evaluation, analysis and design of multiple sanitary sewer lift stations ranging from <br />20 HP to 60 HP and associated force mains. Meeting the FEMA Base Flood Elevation for some of these small locations while <br />maintaining operations and maintenance protocols is a challenge. Under this contract, converted several wet well/dry well <br />systems into submersible stations, requiring significant structural design in order to reuse the existing facilities. This effort <br />is more cost effective than installing a new wet well. Additionally, our team looks carefully at constructability in developing <br />creative solutions that meet all of the client’s needs while maximizing construction dollars. Below are some of the pump <br />stations awarded as task orders to CES under this contract: Design of Pump Stations No. 673, No. 063, No. 659 No. 639 & <br />Generator Replacement PS318, PS464 & PS475. <br />H. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />Water & Sanitary Sewer System Improvements for Utility Analysis <br />Zones (UAZ) 113B, Lauderdale Lakes, FL <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2018 2019 <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Project Engineer As part of the Broward County Water and Wastewater Services (BCWWS) UAZ 111 project, provided utility <br />easement procurement services. Under the existing system configuration, BCWWS was unable to access existing sanitary <br />sewer infrastructure for maintenance and/or repair purposes. Five Letters of No Objection were signed by property owners <br />to obtain 25’ utility easement grants and facilitate installation/maintenance of required sanitary sewer improvements. The <br />effort included coordination with property owners and associations, as well as Esri ArcGIS mapping and utility easement <br />figure development. <br />I. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />BCWWS Master Pump Station 450 Improvements, Lauderdale Lakes, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2019 2019 <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Project Engineer for the construction management services associated with Pump Station 450 Improvements, specifically <br />to provide field observation services and specialty inspections on behalf of the Broward County Building Department. This <br />project includes the installation of line stops, tapping valve/sleeves, temporary bypass pumping system, primary pumps <br />system, jockey pumps system, seal water system, hoisting systems, electrical room motor control center, variable frequency <br />drives, control system, air conditioning and ventilation system, store front door, roll-up door, demolition, and telemetry <br />system. The work includes all associated, site, building, structural, pumping mechanical, building mechanical, electrical and <br />control systems complete, tested, and ready for operation. <br />STANDARD FORM 330 (REV. 8/2016) PAGE 2