Laserfiche WebLink
E-35Proven solutionsResponsive and dependable performance <br />City of Sunny Isles Beach RFQ No. 20-07-01: Continuing Professional Consulting Services (CCNA) <br />F. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />MDWASD PSIP Design of PS 0440, Miami Gardens, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2017 2018 <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Design Engineer for engineering analysis and design for the new Pump Station 0440. This project includes inspecting, <br />designing, and constructing a new pump station to replace the existing pump station in accordance with WASD standards <br />and the EPA Consent decree criteria. <br />G. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />Midway Pump Station, Miami, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2017 2017 <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />As Senior Project Engineer, performed the structural calculations, design and drafting required for the construction of this <br />pump station. This pump station will serve to protect a 43 acre basin bounded by NW 87th Avenue, SR-826, SR-836 and <br />7th Street from flooding. <br />H. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />West Ave. North & South Neighborhood Utility & Resiliency <br />Improvements Design-Build Projects, Miami Beach, FL <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2019 Ongoing <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Project Engineer providing field data collection, sub-basin delineation and data entry in Ad ICPR model for the stormwater <br />master plan and design for a $72M D/B project to address sea level rise for the West Avenue Basin, comprising approximately <br />600 acres of highly urban land use with significant utility conflicts. The project goals are to provide a 10-year level of service <br />with no flooding of finished floors and will require upsizing of nearly every stormwater pipe system, along with modifying <br />and upsizing pump stations. The project is raising 1.2 miles of existing roadway elevation by approximately 30 inches and <br />requires harmonizing streetscape design. The project model is AdICPR Version 4. The utilities being installed include 16,000 <br />LF of water main, 7,050 LF of sanitary gravity sewer, 12,800 LF of storm sewer and an 120,000 GPM stormwater pump <br />station and outfall. <br />I. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />Miami Dade County Public Works Department, Miami, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2010 2010 <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Senior Project Engineer/Inspector performing various field and laboratory testing duties on several projects for various <br />departments of Miami Dade County. The departments include: Public Works, Water and Sewer, Department of Transportation, <br />Seaport, and Aviation. The material testing services requests include: soils, asphalt, concrete, and boring. The various <br />projects Ashraf has performed work on are: Roadway Improvements at NW 74th Street, NW 107th Avenue to NW 84th <br />Avenue, Two Lane Road at SW 34th Street from SW 129th Avenue to SW 128th Avenue, Baroque Estates, SW 30th Street and <br />SW 144th Avenue, MIA South Terminal Dual Taxiway, and the MIA APM System. <br />J. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />Topeekeegee Yugnee Park Maintenance Building, Hollywood, FL PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2010 2010 <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Construction Inspector responsible for direct contractor oversight for the repairs of the Maintenance Building at Topeekeegee <br />Yugnee Park. Several columns inside the building were structurally damaged as a result of spalling over the years, and the <br />concrete slab on grade was damaged due to extensive use of maintenance vehicles. The spalled areas of concrete were <br />repaired, and the concrete slab on grade was repaired by pressure grouting. Structural engineering services included a <br />site visit to observe the damage to the existing column and roof support beams, design for replacement of the damaged <br />structural column, and preparation of Construction Documents, and an Engineer’s Opinion of Probable Construction Costs. <br />K. <br />(1) TITLE AND LOCATION (City and State)(2) YEAR COMPLETED <br />School District of Palm Beach County Program Management, <br />Palm Beach County, FL <br />PROFESSIONAL SERVICES CONSTRUCTION (If applicable) <br />2020 Ongoing <br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE X Check if project performed with current firm <br />Field Construction Manager responsible for overseeing construction/renovation activities at various Palm Beach County <br />Schools in West Palm Beach, to include supervising and inspecting contractor’s work to assure compliance with specifications, <br />establishing onsite solutions to unforeseen issues found in the field, conducting onsite meetings with contractor and sub- <br />contractors, reviewing shop drawings and Coordinating with City Public Works departments to ensure compliance. <br />STANDARD FORM 330 (REV. 8/2016) PAGE 2