12. NAME 113. ROLE IN THIS CONTRACT 1 14. YEARS EXPERIENCE
<br />Tom Holley, CHMM, CIH, Environmental Engineer: Senior Certified I a. TOTAL b. WITH CURRENT FIRM
<br />CSP, FLAC, MRSA I Industrial Hygienist (CIH)/QA/QC Reviewer 129 4.5
<br />15. FIRM NAME AND LOCATION (City and State
<br />Terracon Consultants, Inc. (Tampa, FL)
<br />16. EDUCATION DEGREE AND SPECIALIZATION 17. CURRENT PROFESSIONAL REGISTRATION STATE AND DISCIPLINE
<br />B.S./Biology Florida/Licensed Asbestos Consultant Florida/Licensed Mold Assessor
<br />18. OTHER PROFESSIONAL QUALIFICATIONS Publications. Organizations, Training, Awards, etc.
<br />Certifications: Certified Hazardous Materials Manager- Master Certified Industrial Hygienist- 9275CP
<br />Certified Safety Professional- 22954 EPA/AHERA Asbestos Inspector,
<br />Management Planner, Designer, Supervisor NIOSH 582 Sampling & Analysis of Airborne Dusts
<br />OSHA 40 -Hour HazWoper OSHA 30 -Hour Construction Safety and Health
<br />OSHA 10 -hour Construction Safety and Health eRAILSAFE Contractor
<br />Affiliations: American Board of Industrial Hygiene
<br />Institute of Hazardous Materials Managers
<br />1 TITLE AND LOCATION (City and State
<br />Tampa Housing Authority Environmental Consulting Contract
<br />Tampa, FL
<br />a 11S RRIEF DESCRIPTION /Brief scope. size. cost. etc.: AND SPECIFIC ROLE
<br />Board of Certified Safety Professionals
<br />YEAR
<br />Ongoing
<br />N/A
<br />® Check if proiect performed with current firm
<br />ZI
<br />Senior Industrial Hygienist. Terracon conducted a limited indoor air quality (IAQ) assessment of 18 separate locations to establish
<br />an IAQ baseline within the facility. The IAQ parameters measured in designated indoor and outdoor locations included CO, CO2,
<br />temperature, RH, airborne bioaerosols, and surface fungal spores, structures, hyphae, and other particulates. The bioaerosol
<br />samples were collected from representative indoor locations and the outdoor environment using a spore trap sampling technique.
<br />Terracon provided results, conclusions, and recommendations (utilizing a unique algorithmic risk ranking) on the observed
<br />conditions. In addition, Terracon presented the findings in a town -hall type setting in the client's Tallahassee conference Hall. Firm's
<br />Fee: $47,000
<br />STANDARD FORM 330 (REV. 8/2016) 51
<br />Project Manager. Responsible for all services under this continuing contract which includes providing environmental consulting,
<br />lead and asbestos testing, risk assessment, hazard reduction design, abatement monitoring and site assessment services on an
<br />as -needed basis. Firm's Fees: on a task -by -task basis
<br />t1 TITLE AND LOCATION Ci and State !2; YEAR COMPLETED
<br />Dade College Building 1000, 1St and 31d Floors Part B PROFESSIONAL SERVICES CONSTRUCTION (If applicable)
<br />Eduardo J. Padron Campus 2019 N/A
<br />,Miami
<br />Miami, FL
<br />3 BRIEF DESCRIPTION :Briefscope, size, cost etc.; AND SPECIFIC ROLE N Check if project performed with current firm
<br />b.
<br />APR/Quality Reviewer. Terracon performed a limited, interior asbestos survey, to assess potential hazardous materials that may
<br />be present in Building 1000, to accommodate the planned future development activities at the facility. Building components were
<br />surveyed and homogeneous areas of suspect asbestos -containing materials (ACM) were visually identified and documented.
<br />Suspect ACM samples were collected in general accordance with the sampling protocols outlined in EPA regulation 40 CFR 763
<br />(Asbestos Hazard Emergency Response Act, AHERA). Asbestos samples were delivered to an accredited laboratory for analysis.
<br />Suspect ACM samples were analyzed by Polarized Light Microscopy (PLM). Firm's Fee: $8,100
<br />(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br />Central District Wastewater Treatment Plant (WWTP) PROFESSIONAL SERVICES CONSTRUCTION (1fapplicable)
<br />Miami, FL 2019 N/A
<br />(3) BRIEF DESCRIPTION Briefscope, size, cost, etc.; AND SPECIFIC ROLE - Check if project performed with current firm
<br />APR/Quality Review. Terracon conducted a pre -demolition asbestos survey on the interior and exterior of the structures located at
<br />c•
<br />the Central District WWTP located in Miami. The plant was initially constructed in 1966, but it is unknown when the specific structures
<br />were constructed. The estimated SF of the two buildings surveyed is 1,400 SF. The structures consisted of concrete block exterior
<br />walls, poured in place concrete walls atop multiple concrete slabs and concrete ceiling. Our survey was conducted by an Asbestos
<br />Hazard Emergency Response Act (AHERA)-accredited asbestos inspector. Suspect ACM samples were collected in general
<br />accordance with the sampling protocols outlined in the Environmental Protection Agency (EPA) regulation 40 CFR 763 (AHERA).
<br />Samples were delivered to an accredited laboratory for analysis by PLM. Firm's Fee: $64,492
<br />1 � TITLE AND LOCATION (City and State! t2) YEAR COMPLETED
<br />f
<br />Gadsden County Correctional Institute PROFESSIONAL SERVICES CONSTRUCTION lfa licable
<br />Quincy, FL 2017 N/A
<br />(3) BRIEF DESCRIPTION Briefscope, size, cost, etc.) AND SPECIFIC ROLE ® Check if project performed with current firm
<br />ZI
<br />Senior Industrial Hygienist. Terracon conducted a limited indoor air quality (IAQ) assessment of 18 separate locations to establish
<br />an IAQ baseline within the facility. The IAQ parameters measured in designated indoor and outdoor locations included CO, CO2,
<br />temperature, RH, airborne bioaerosols, and surface fungal spores, structures, hyphae, and other particulates. The bioaerosol
<br />samples were collected from representative indoor locations and the outdoor environment using a spore trap sampling technique.
<br />Terracon provided results, conclusions, and recommendations (utilizing a unique algorithmic risk ranking) on the observed
<br />conditions. In addition, Terracon presented the findings in a town -hall type setting in the client's Tallahassee conference Hall. Firm's
<br />Fee: $47,000
<br />STANDARD FORM 330 (REV. 8/2016) 51
<br />
|