Laserfiche WebLink
AUTHORIZED FOR LOCAL REPRODUCTION STANDARD FORM 330 (1/2004) PAGE 6 <br />MANDATORY USE DATE OF FORM 6/2004 <br /> <br />F. EXAMPLE PROJECTS WHICH BEST ILLUSTRATE PROPOSED TEAM'S <br />QUALIFICATIONS FOR THIS CONTRACT <br />(Present as many projects as requested by the agency, or 10 projects, if not specified. <br />Complete one Section F for each project.) <br />20. EXAMPLE PROJECT KEY <br />NUMBER <br />1 <br />21. TITLE AND LOCATION (City and State) <br />South Florida Water Management District Structure Inspection Program – <br />Underwater Component <br />Various sites in South Florida <br />22. YEAR COMPLETED <br />PROFESSIONAL SERVICES <br />2020 <br />CONSTRUCTION (If applicable) <br />NA <br />23. PROJECT OWNER'S INFORMATION <br />a. PROJECT OWNER <br />South Florida Water Management District <br />b. POINT OF CONTACT NAME <br />Tjerk van Veen <br />c. POINT OF CONTACT TELEPHONE NUMBER <br />561.682.2717 <br />24. BRIEF DESCRIPTION OF PROJECT AND RELEVANCE TO THIS CONTRACT (Include scope, size, and cost) <br />Underwater Engineering Services, Inc. (UESI), UESI was selected by the South Florida Water Management District (SFWMD) to perform <br />underwater condition assessments of water control structures. The work orders to date have included the inspection of 23, 36 and 38 <br />structures for FY17-18, FY18-19 and FY19-20, respectively, including culverts, spillways, pump stations, boat locks, and weirs. The <br />professional engineering fee to date has totaled $1M. A UESI Florida professional engineer was on site at all times supervising the dive <br />operation and providing an engineering assessment. The diving operation was surface supplied with full video and audio communication. <br />As part of the deliverable UESI furnished raw videos, edited with title pages. The inspection data and photographs were entered into the <br />District’s Archival Tool. A metadata file (in Excel form) was provided that listed the team members, dates, and a summary of the structure <br />deficiencies and recommended repairs. <br />This project had underwater and topside condition assessments of water control structures – which would be similar to bridge elements or <br />seawalls. Ratings followed a system set up by the District. Inspections for Sunny Isles would follow those set up by FHWA and FDOT, <br />which would be similar. <br />This project included recorded video and audio of the inspection, which may or may not be required for the Sunny Isles project. <br />Team experience: <br />Mr. O’Connor was the Project Manager and on-site engineer for this work. Mr. Faulk was dive supervisor for approximately 30% of this <br />work. Mr. Trotta was dive supervisor for approximately 30 structures, and performed the inspection of several structures. <br /> <br />25. FIRMS FROM SECTION C INVOLVED WITH THIS PROJECT <br />a. <br />(1) FIRM NAME <br />UESI, Inc. <br />(2) FIRM LOCATION (City and State) <br />Fort Pierce, FL <br />(3) ROLE <br />Prime <br />b. <br />c. <br /> <br />Section E - Page | 84