Bore Tech Utilities & Maintenance <br />RFP 22.04.01 <br />• 2 x 1.25" conduits approx. <br />82' between M01 & Heritage Park Garage. <br />• 2 x 1.25" conduits approx. <br />222' between M03 & Golden Shores Community Park. <br />• 2 x 1.25" conduits approx. <br />737' between M10 & Senator Gwen Margolis Park. <br />• 2 x 1.25" conduits approx. <br />533' between M12 & Samson Ocean Front Park <br />• 2 x 1.25" conduits approx. <br />559' between M13 & Town Center Park <br />• 2 x 1.25" conduits approx. <br />333' between M14 & Pier Park <br />• 2 x 1.25" conduits approx. <br />143' between M14 & Gateway Park Garage <br />• 2 x 1.25" conduits approx. <br />539' between M16 & Intercoastal Park <br />• 2 x 1.25" conduits approx. <br />421' between M17 Intercoastal Park <br />• 2 x 2" conduits approx. 321' <br />between M08 & Data Center D2 <br />• 2 x 2" conduits approx. 321' <br />between M09 & Data Center D1 <br />Warning Tape will be placed for all buried cable installation process except when <br />directional boring operation are used and will be as Extra Stretch terra tape, Minimum <br />of six inches (6") wide, Orange in color with black lettering which reads "Caution Buried <br />Fiber Optic Cable Below". Placed in the Trench a minimum of twelve inches (12") above <br />all conduit/ fiber <br />Unless otherwise specified by the Contractor's project engineer the depth of buried <br />cable or wire placed, measured from the top of the cable or wire to the surface of ground <br />or rock will be a minimum depth in soil (Mainline) — 36", <br />Minimum depth at ditch crossings 36", Minimum depth in rock 24" (152 mm) Rock to <br />surface. <br />FDOT or other authority having jurisdiction may require a deeper requirement for <br />minimum depth. In the event of conflicting requirements, the more stringent depth <br />requirement shall be used. The conduit shall be placed in such a way as to maintain a <br />gradual grade down away from buildings and other major structures. <br />All conduit installed will be proofed and include the installation of a continuous, jet -line <br />pull -string. Duct proofing will ensure new conduit are continuous, free from dirt and <br />debris and conduit is in good usable condition. All conduit ends shall be properly sealed <br />with mechanical duct plugs. Duct plugs will be Jack -moon type or equal. A #12 AWG <br />insulated solid trace wire will be placed along with all conduits put in place. This trace <br />wire will maintain continuity from end station to end station. We will use vaults/hand <br />holds for joining the trace wire. Inner duct, where required will be of the corrugated type <br />and orange in color. Inner duct requirements (size and amount) will be determined by <br />the Project Engineer. <br />All conduits will be stubbed up underneath the bottom of each hand hole leaving at least <br />8" but no more than 12" of visible conduit exposed. Conduit and inner ducts will be <br />capped prior to use. After use they will be plugged appropriately to maintain the integrity <br />of the conduiUinner duct from dirt and water. All splice points, vaults, hand holes, and <br />7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.