Bore Tech Utilities & Maintenance <br />• Town Center Park <br />• Pier Park <br />• Gateway Park Garage <br />Fiber -Optic Cable <br />We will be installing three size fibers per project design: <br />1. 12ct single mode dielectric fiber <br />2. 24ct single mode dielectric fiber <br />3. 144ct single mode dielectric fiber <br />4. 288ct single mode dielectric fiber <br />RFP 22-04-01 <br />All cable, unless specifically called out, for shall be single -mode cable, rated for the <br />environment in which it is installed. Installations shall be Corning OSP rated dielectric. <br />All cables shall be loose tube. Coil a minimum of 50 feet of cable at each HH for a dead- <br />end fiber cable Coil a min of 100 feet in all HH's where no dead-end fiber cable will be <br />terminated <br />All fibers will be tagged and labeled at each splice location, fiber termination panel and <br />building entrance. Tags shall read cable size, count and origin. All fibers in the cables <br />shall be usable fibers and shall be free of surface imperfections and occlusions, to meet <br />or exceed all the optical, mechanical, and environmental requirements contained in this <br />specification. All cables shall be free of material or manufacturing defects and <br />dimensional non-uniformity. <br />Each fiber optic outside plant cable for this project shall be all -dielectric, dry water - <br />blocking material, duct type, with loose buffer tubes, and shall conform to these special <br />conditions. The cable shall be qualified as compliant with Chapter XVII, of Title 7, Part <br />1755.900 of the Code of Federal Regulations, "REA Specification for Filled Fiber Optic <br />Cables." <br />The cable shall be tested in accordance with TIA/EIA-455-3A (FOTP-3), "Procedure to <br />Measure Temperature Cycling Effects on Optical Fiber, Optical Cable, and Other <br />Passive Fiber -Optic Components." The average change in attenuation at extreme <br />operational temperatures (-40 C to +70 C) will not exceed 0.05 dB/km at 1550 nm. <br />The magnitude of the maximum attenuation change of each individual fiber will not be <br />greater than 0.15 dB/km at 1550 nm. This figure includes an allowance of up to 0.05 <br />dB/km for measurement repeatability. <br />We will be placing approx. 33,294' of fiber optic cable including slack in existing conduit <br />and in newly installed conduit of which 2,000' of fiber cable and slack will be pulled <br />through buildings. Of the fiber placed approx. 7,814' of 12ct will be placed, approx. <br />22,139' of 144ct fiber will be placed and approx. 3,341' of 288ct fiber will be placed <br />l:] <br />