Laserfiche WebLink
<br />Future CSIB Offices  <br />18050 Collins Avenue, Sunny Isles Beach, Florida 33160  <br /> <br />   <br />Prepared by: Gallagher Bassett Services, Inc. Page 2 <br /> <br />2.0 METHODS  <br />The specified interior building materials were inspected for suspect ACM, unless otherwise noted. Each  <br />observed suspect material was described and sampled. Samples were collected according to procedures  <br />established by EPA in 40 CFR 763.    <br />Samples were sent to EMSL Analytical, Inc. in Fort Lauderdale, Florida for analysis. Upon arrival at the  <br />laboratory, the samples were logged‐in and stored for analysis. Analyses were performed using the  <br />polarized light microscopy (PLM) method of asbestos detection using guidelines and procedures  <br />established in the Method for the Determination of Asbestos in Bulk Building Materials (EPA‐600/R‐93‐ <br />116 July, 1993). Results were provided as percent (%) asbestos by volume. Samples found to contain  <br />greater than 1% asbestos were considered positive and listed as ACM.   <br />LIMITATIONS OF SURVEY  <br />This asbestos inspection report has been prepared by GBTS in a manner consistent with industry standards  <br />exercised by members of the profession practicing under similar conditions. No other warranty, expressed  <br />or implied is made. The intent of this survey report is to assist the owner or client in locating ACM. Under  <br />no circumstances is this survey to be utilized as a proposal or a project specification document without  <br />the expressed written consent of GBTS.   <br />The survey was conducted to identify suspect ACM in accessible interior areas of the subject area. If other  <br />areas at this location (i.e. roofing components) are to be impacted during planned or future renovations,  <br />a separate asbestos survey of these areas will be required. Some ACM may not have been discovered due  <br />to inaccessibility or missing/incomplete plans. Suspect materials discovered subsequent to the issue of  <br />this survey report should be sampled and analyzed to determine asbestos content and to initiate  <br />appropriate responses.  <br />Analyses were carried out by PLM. While the most commonly accepted analytical method for detecting  <br />asbestos in bulk materials, PLM is known to have limited resolution and may not detect extremely small  <br />asbestos fibers. Certain materials, notably vinyl floor tiles, may contain extremely fine asbestos fibers that  <br />are beyond the resolution of PLM.  <br />GBTS's interpretations and recommendations are based upon the results of sample collection and  <br />analyses in compliance with environmental regulations, quality control and assurance standards, and the  <br />scope of work as indicated in GBTS’s proposal. The results, conclusions, and recommendations contained  <br />in this report pertain to conditions observed at the time of the survey. Other conditions elsewhere in the  <br />subject building(s) may differ from those in the inspected/surveyed locations and, such conditions are  <br />unknown, may change over time, and have not been considered.  <br />This report was prepared solely for the use of GBTS’s client, and is not intended for use by third party  <br />beneficiaries. The client shall indemnify and hold GBTS harmless against liability for loss arising out of or