Laserfiche WebLink
condition. Please address this issue. <br />6. The existing elevations in the ROW on the survey, 6.16, 6.22, vary from the existing <br />elevations shown on C-300, 4.59, 4.64. Please address this. Please submit a survey <br />that is consistent with the civil plans. <br />7. The survey states that the elevations are in NGVD. C-300 note #11 states it is in NGVD; <br />however, the elevations are inconsistent. Please address this on C-300. <br />8. Revisit the proposed grades for the ADA stall. Show elevations at all four corners of the <br />stall and access aisle not exceeding 2% slope in any direction. Currently, the 8.97 TOC <br />will exceed the allowable slope with the elevations shown. <br />9. Provide the FDOT curb ramp and FDOT detectable warning strip details. Please provide <br />the curb detail(s). <br />10. Dimension the front and back of the building entrances and walkways and label the <br />uses of the areas. <br />11. Label and dimension if there is an access to the beach. <br />12. Add the zigzag line hatch to the legend. Clarify on the plan the difference between the <br />material denoted by the zigzag line versus the sod/lawh hatch. <br />Thank you very much. <br />Regards, <br />Heidi Belle Henderson, P.E. <br />Engineer <br />Direct: 305.792.1817 <br />Main: 305.792.1830 <br />Cellular: 305.450.2971 <br />hhendersonCcDsibfl.net <br />Government Center <br />18070 Collins Avenue <br />Sunny Isles Beach, FL 33160 <br />www.sibfl.net <br />358 <br />