Laserfiche WebLink
Calvin, Giordano & Associates, Inc. Memorandum <br />E X C E P T I O N A L S O L U T 1 0 N S- <br />driveway to access adjacent property (18291 Collins Av) calls for R6-2R, revise callout. Please clarify where <br />the R6-1 sign is on sheet C-200. Please address this issue. <br />5. Please note that a traffic control device is needed for the SIB approach entering the adjacent traffic circle. <br />Please note -that pedestrians may be present as a sidewalk is present. Please confirm that the traffic circle at <br />the southern parcel operates as a regular roundabout. <br />LSN LAW Response: Please refer to Sheets C-200 and C-201 for yield details and signage. <br />CGA Response: Satisfied. Consider adding W11-2 sign to warn drivers about pedestrians crossing. <br />6. Please clarify what the bar between the Do Not Enter (R5-1) signs is. <br />LSN LAW Response: Please refer to sheet C-400 for a slot drain callout. <br />CGA Response: Satisfied. <br />7. Stop bars shall be 4 feet behind the sidewalk per MUTCD. Please add dimensions. <br />LSN LAW Response: Please refer to Sheet C-200 for stop bar dimension of 4 feet from the edge of sidewalk <br />CGA Response: Satisfied. <br />8. Please clarify if ramps are proposed at the end of the ADA parking space. <br />LSN LAW Response: Please refer to Sheet C-200 for ramp CR-C <br />CGA Response: Satisfied. Ramps shall comply with ADA requirements. <br />9. A detail of sign R3-5r was included in sheet C-201; however, the sign was not used. Please clarify. <br />LSN LAW Response: Please refer to Sheet C-201 for R3-5r detail. <br />CGA Response: R3-5R was removed. The sign is not shown in sheet C-200. <br />10. Please clarify if vehicles will be allowed to exit the site via the southern property. <br />LSN LAW Response: Yes, vehicles have egress access to the site located to the South. This site is <br />located within the same property limits as the Sales Center. <br />CGA Response: Satisfied. <br />11. Please include cross and running slopes at the sidewalks showing compliance with ADA requirements. <br />LSN LAW Response: Please refer to sheet C-400. <br />CGA Response: Satisfied. Elevations provided in sheet C-300. <br />12. Detectable warnings are needed at the WB approach to cross in the north -south direction. Please confirm the <br />slopes are ADA compliant. <br />Revised: 08/2S 360 <br />