Laserfiche WebLink
RFQ # 26-07-01 | CITY OF SUNNY ISLES BEACH 116 <br />CES CONSULTANTS, INC. <br />David Hoot is a skilled professional with 50 years of experience. David has successfully functioned in <br />many leadership and operational roles and has an extensive background in civil and environmental <br />engineering. He has significant experience in project management and direction of civil/environmental <br />engineering design and plan preparation involving neighborhood improvement; sustainability and <br />resiliency; site development and pre-development services; roadway and transportation-related <br />design; utilities and infrastructure improvements; water and wastewater transmission, collection <br />and treatment systems; stormwater pipe/culvert design, environmental permitting and stormwater <br />management; environmental impact studies and assessments; and CEI and construction management. <br />David has directed, managed, designed, or provided quality control for various multidisciplinary <br />water, wastewater, stormwater and water resource systems/projects throughout his career; and has <br />provided professional/consulting services related to wastewater and stormwater system evaluation, <br />technical support and design of various types and sizes of pump/lift stations and collection and FM <br />systems, including reuse, and environmental restoration improvements and sustainability projects in <br />the public and private sectors in Florida and the Southeast US. <br />MDWASD Engineering, Design and Related Services for the Local Pump Station Improvement <br />Program, Miami-Dade County, FL: Technical Advisor & QA/QC for design of multiple sanitary sewer <br />lift stations ranging from 20 HP to 60 HP and associated force mains. The challenges found in <br />designing these upgrades relate to two items. First, meeting the FEMA Base Flood Elevation for some <br />of these small locations while maintaining operations and maintenance protocols is a challenge. <br />Under this contract, we have converted several wet well/dry well systems into submersible stations. <br />These conversions are requiring significant structural design in order to reuse the existing facilities. <br />This effort is more cost effective than installing a new wet well. The engineering work includes pump <br />stations PS-0673, PS-0132, PS-0659, PS-0063, PS-0348, PS-0318, PS-0464, PS-0475 and PS-0639. <br />MDWASD Professional Services for the Pump Station Improvement Program (PSIP) & Associated <br />Force Mains, Miami-Dade County, FL: As Project Director/Technical Advisor, provided project oversight <br />and guidance for scope and fee development, client coordination, site & system evaluation for cost, <br />engineering analysis, design, coordination, permitting and management for the rehabilitation and <br />replacement of multiple pump stations for the PSIP. The project consisted of existing pump station <br />inspection, coordination of survey and geotechnical services, design of pump station rehabilitation <br />or replacement, design of connecting force mains, permitting, and limited construction services. The <br />engineering work included PS 0449, PS 0147, PS 0331, Force Main 0592 (24-inch), PS 0440, PS 0336, <br />PS 0609, PS 0081, PS 1026 and PS 1065. <br />NW 13th Street 36-inch Force Main Replacement, Fort Lauderdale, FL: Sr. Engineer for the design, <br />permitting, construction, testing and startup of a new 36” force main along NW 13th Street in an <br />urban area of Fort Lauderdale, including connections to the existing pipe and reconnection of <br />Pump Stations A-28 and A-29. The project also included the design, permitting, construction, and <br />installation of a new plug valve and piping near NE 14th Avenue and 11th Street to replace the <br />existing inoperable valve and provide isolation to perform the required tie-in work. <br />NW 12th Avenue Force Main Replacement, North Miami, FL: Sr. Engineer for the design, permitting, and <br />construction of 10,500 LF of 10- and 12-inch replacement force main in NW 12th Avenue extending from <br />NW 95th Street to NW 125th Street. The project replaced aging, asbestos-cement and cast iron force <br />mains with corrosion resistant PVC pipe. A number of private force main connections required relocation <br />and reconnection to the new force main, as well as planning for uninterrupted service during construction. <br />DAVID HOOT, PE <br />Senior Vice President; Technical Advisor & QA/QC <br />YEARS EXPERIENCE <br />50 <br />EDUCATION <br />BS, Civil Engineering, <br />Environmental Engineering & <br />Water Resources, Michigan Tech <br />University, 1976 <br />REGISTRATIONS & <br />CERTIFICATIONS <br />Florida Professional Engineer <br />#35970, 1985 <br />Georgia Professional Engineer <br />#13518, 1982 <br />PROFESSIONAL AFFILIATIONS <br />American Management Association <br />American Water Works Association <br />American Water Resources <br />Association <br />Ducks Unlimited, Wetland <br />Conservation <br />Florida Engineering Society <br />Solid Waste Association of North <br />America <br />Water Environment Federation <br />SPECIAL TRAINING <br />OSHA 40-Hour Hazmat/Health & <br />Safety Training <br />OSHA 8-Hr. Hazmat Supervisor/ <br />Mgmt. Training <br />Wetlands Identification & <br />Permitting <br />Environmental & Wetlands <br />Permitting <br />Solid & Hazardous Waste Mgmt. <br />Short Course