My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
R.E. Chisholm Architects. Inc.
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
RFQ
>
(26-07-01) Continuing Professional Architectural & Engineering Consulting Services (CCNA)
>
PROPOSALS
>
R.E. Chisholm Architects. Inc
>
R.E. Chisholm Architects. Inc.
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/31/2026 1:36:37 PM
Creation date
8/31/2026 1:34:55 PM
Metadata
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
123
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Pompano Beach City Lot (Senior Center) <br />2005 NW 9th Street, Pompano Beach, Broward County, Florida <br />A former filling station/automotive dealership <br />(Southern Oil Service) occupied the northeast <br />portion of the property from approximately 1958 to <br />1962. During construction activities for the City of <br />Pompano Beach Senior Center, the construction <br />company found two 1,000-gallon capacity <br />underground storage tanks (USTs) and associated <br />piping that previously unknown. <br />In response to the discovery of the USTs, PSI <br />mobilized to the site to begin tank closure and <br />assessment activities. PSI successfully removed the <br />USTs from the property and were able to perform <br />the tank closure activities without delaying the <br />construction occurring on the property. During <br />assessment activities, petroleum contamination in <br />the groundwater was identified. PSI submitted a <br />Discharge Reporting Form (DRF) and Tank Closure <br />Assessment Report (TCAR), registered the USTs with <br />the Florida Department of Environmental Protection <br />(FDEP) on the City of Pompano Beach’s behalf, and <br />began Site Assessment Report (SAR) activities. <br />As part of the SAR, PSI created and submitted, on <br />behalf of the City, an application for environmental assessment and remediation license to the Broward County <br />Board of County Commissioners. PSI then installed five shallow and one deep monitoring well to delineation the <br />impacted groundwater in both the horizontal and vertical dimensions. PSI conducted four sampling events over <br />42
The URL can be used to link to this page
Your browser does not support the video tag.