My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Reso 2008-1356
SIBFL
>
City Clerk
>
Resolutions
>
Regular
>
2008
>
Reso 2008-1356
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/16/2010 3:52:39 PM
Creation date
11/18/2009 2:26:35 PM
Metadata
Fields
Template:
CityClerk-Resolutions
Resolution Type
Resolution
Resolution Number
2008-1356
Date (mm/dd/yyyy)
12/18/2008
Description
Agmt w/Allbrite Electric Srv, Purchase/Install Frequency Modulator for Govt Ctr
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
44
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />Projected Resultants <br /> <br />Projected Resultants # FS080408.A690xl <br /> <br />1*. Voltage Improvement in Line(V): 5 <br />EF will improve and stabilize voltage supplied to the load, thus <br />improved efficiency and longevity of the facility's load, and reduction <br />of heat losses, KWD and Kwh. <br />2*. Voltage Improvement in Transformer(V): 4 <br />EF will improve and stabilize voltage in the transformer, thus <br />improved efficiency and reduction of heat losses. <br />3*. Increased Revenue Due to Voltage Improvement(%): 4 <br />EF will improve and stabilize voltage, thus improved efficiency and <br />longevity of the facility's load and reduction of losses, failure, <br />breakdown and maintenance. <br />4*. Line Current Reduction(A): 63 <br />EF will reduce line current through reduction of reactive current and <br />phase imbalance, thus increasing system efficiency and reducing <br />KWD and Kwh. <br />5*. Reduction of Losses(%): 10 <br />EF will reduce losses such as line, Hysteresis and Eddy Current, thus <br />increasing system efficiency and reducing KWD and Kwh. <br />6*. Annual Reduced Energy Losses(KWH): 614 <br />EF will reduce losses such as line, hysteresis and Eddy Current, thus <br />increasing system efficiency and reducing KWD and Kwh. <br />7*. Increased Load Capability(KW): 19 <br />EF will reduce Reactive/nonproductive Power and distribution losses <br />while improving voltage and balancing the phases, thus allowing <br />more productive power can be utilized. <br />8*. Increase in Feeder Capacity(KVA): 22 <br />EF will reduce Reactive/nonproductive Power and distribution losses <br />while improving voltage and balancing the phases, thus allowing <br />more capacity for additional load. <br />9*. New Apparent Power(KVA): 384 <br />EF will reduce Apparent Power and distribution losses while improving <br />voltage and balancing the phases, thus allowing more capacity for <br />additional load. <br />10*. New Real Power(KW): 352 <br />EF will reduce Real Power, Peak Demand, and distribution losses <br />while improving voltage and balancing the phases, thus allowing <br />more capacity for additional load. <br />11*. New Reactive Power(KVAR): 102 <br />EF will reduce Reactive/nonproductive Power and the losses in the <br />system, while improving voltage and balancing the phases, thus <br />allowinq more capacity for additional load. <br /> <br />21 <br />
The URL can be used to link to this page
Your browser does not support the video tag.