<br />
<br />. NAME
<br />Cristina M. Gonzalez, P.E.
<br />
<br />E. RESUMES OF KEY PERSONNEL PROPOSED FOR THIS CONTRACT
<br />(Complete one Section E for each key person.)
<br />13. ROLE IN THIS CONTRACT
<br />Principal
<br />
<br />14. YEARS EXPERIENCE 28
<br />
<br />24
<br />
<br />b. WITH CURRENT FIRM
<br />22
<br />
<br />a. TOTAL
<br />
<br />15. FIRM NAME AND LOCATION (City and State)
<br />
<br />Langan Engineering & Environmental Services I Miami Lakes, Florida
<br />
<br />16. EDUCATION (DEGREE AND SPECIALlZA TlON)
<br />Cornell University, Master of Engineering in Civil
<br />Engineering (Geotechnical) 1/82
<br />University of Miami, Bachelor of Science in Civil
<br />Engineering, 12/79
<br />
<br />17. CURRENT PROFESSIONAL REGISTRATION (STA TE AND DISCIPLINE)
<br />Registered Professional Engineer: FL #41915
<br />
<br />18. OTHER PROFESSIONAL QUALIFICATIONS (Publications, Organizations, Training, Awards, etc.)
<br />
<br />19. RELEVANT PROJECTS
<br />
<br />a.
<br />
<br />(2) YEAR COMPLETED
<br />PROFESSIONAL SERVICES CONSTRUCTION (if applicable)
<br />On- oing
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE t8] Check if project performed with current firm.
<br />Lead engineer on the 36 and 26-story towers. Our extensive evaluation and interaction with the Structural Engineer provided the
<br />Owner substantial savin s with the use of shallow hi h-capacit iles for support of both towers. Cost of work: $1,600,000
<br />(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br />Turnberry Ocean Colony Development, Sunny Isles Beach, Florida PROFESSIONAL SERVICES CONSTRUCTION (if applicable)
<br />2007
<br />
<br />(1) TITLE AND LOCATION (City and State)
<br />Fontainebleau II and III Towers, Miami Beach, Florida
<br />
<br />b.
<br />
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE t8] Check if project performed with current firm.
<br />This development is to consist of twin 38-story towers and a connecting submerged 3-level parking garage,
<br />compression, tension and lateral load testing for different size of augercast piles. Cost of work: $450,000
<br />
<br />Performed
<br />
<br />c.
<br />
<br />(2) YEAR COMPLETED
<br />PROFESSIONAL SERVICES CONSTRUCTION (if applicable)
<br />On- oing
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE t8] Check if project performed with current firm.
<br />Project Principal The project is under-construction and consists of a 55-story residential tower in the southern end of Sunny Isles
<br />Beach. The foundation design for this project consists of the use of 30-inch-diameter, 145 ft to 150 ft long augered cast-in-place
<br />(ACIP) piles extended beyond the compressible sand and weakly cemented layers typically encountered in the Sunny Isles
<br />Beach area. The ACIP pile load testing program included the installation of a deep O-cell embedded jack, approximately 24 ft
<br />above the tip of the test pile, The services also included the collection and testing of the near-surface materials for compatibility
<br />with the beach sand, as part of the soil compatibilit performed b the pro'ect civil en ineer. Cost of work: $250,000
<br />(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br />Dolphin Stadium, Miami Gardens, Florida PROFESSIONAL SERVICES CONSTRUCTION (if applicable)
<br />On-going
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE t8] Check if project performed with current firm,
<br />The Home of the Miami Dolphins and Florida Marlins is partially underlain by loose sands and partially by loose sands with a thin
<br />limerock layer. Supervised the subsurface investigation and assisted in developing the site stabilization for recommending
<br />shallow strip footings for the highly varying column loads. Reported on the subsurface conditions and developed a comparative
<br />foundation cost analysis comparing preloading, vi bra-replacement and dynamic compaction. Assisted in the preparation of the
<br />site preparation specifications, preload design, and preload monitoring and evaluation. Performed footing subgrade inspections,
<br />testing, and reporting. The engineering work also included the investigation, design, supervision and analysis of a full-scale field
<br />test to determine the impact and effectiveness of a 10-ton vibrato roller on sand with depth. Cost of work: $365,000
<br />(1) TITLE AND LOCATION (City and State) (2) YEAR COMPLETED
<br />Fairfield Dadeland, Miami, Florida PROFESSIONAL SERVICES CONSTRUCTION (if applicable)
<br />2003
<br />
<br />(1) TITLE AND LOCATION (City and State)
<br />Solis Resort, Sunny Isles Beach, Florida
<br />
<br />d.
<br />
<br />
<br />(3) BRIEF DESCRIPTION (Brief scope, size, cost, etc.) AND SPECIFIC ROLE t8] Check if project performed with current firm.
<br />Ms, Gonzalez value engineered the foundations of this 26-story condominium tower and garage podium, increasing the pile
<br />capacity nearly 400% and reducing the lengths. Savings on the foundations alone were over $750,000. Also provided
<br />environmental engineering services and dewatering consultation, assisting with providing dewatering solutions and obtaining the
<br />dewaterin permit from various overnmental a encies.
<br />
<br />STANDARD FORM 330 (6/2004) PAGE 2