My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
Specifications Vol. II
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
ITB
>
(09-09-01) Streetscape Improvements 175th Ter & 183rd St
>
Specifications Vol. II
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/12/2011 11:13:16 AM
Creation date
5/12/2011 11:12:16 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Median Closure
Bid No. (xx-xx-xx)
09-09-01
Project Type (Bid, RFP, RFQ)
Bid
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
<br />.... <br /> <br />. <br /> <br />-, <br />. <br /> <br />. <br /> <br />Do not core hardened concrete for determining pay adjustments when the <br />28-day acceptance cylinder strength test results are less than 500 psi [3.5 MPa] or 10%, <br />whichever is greater, below the specified minimum strength. <br />When the Contractor submits acceptable core samples to the Engineer for <br />testing, the Engineer will determine payment reductions based upon th~ results of the <br />strength tests. Both the Contractor and the Department shall accept the results of strength <br />tests of the drilled cores, subject to 346-11.5 and 346-11.6, as final and in lieu of the <br />cylinder strength test results for determining pay adjustments. <br />346-11.3 Coring for Determination of Pay Adjustments: Obtain the cores In <br />accordance with 346-10.3. <br />346-11.4 Core Conditioning and Testing: The Department will test the cores In <br />accordance with 346-10.4. <br />346-11 .5 Core Strength Representing Equivalent 28-Day Strength: For cores tested <br />no later than 42 days after the concrete was cast, the Engineer will accept the core <br />strengths obtained as representing the equivalent 28-day strength of the lOT of concrete <br />in question. The Engineer will calculate the strength value to be the average of the <br />compressive strengths of the three individual cores. The Engineer will accept this strength <br />at its actual measured value. <br />346-11.6 Core Strength Adjustments: For cores tested later than 42 days after the <br />concrete was cast, the Department will establish the equivalency between 28-day strength <br />and strength at ages after 42 days based on test data developed by a Department <br />approved testing laboratory to relate strength at the actual test age to 28-day strength for <br />the particular class of concrete and design mix represented by the cores. Obtain such data <br />at no additional expense to the Department. When such data is not available and cannot be <br />produced, as determined by the Department, the Department will determine the equivalent <br />28-day strength by adjusting the tested core strengths according to the following <br />relationship: <br />346-11.6.1 Portland Cement Concrete without Pozzolan or Slag: <br />Equivalent 28-Day Strength, f' c (28) = 1/F (Average Core Strength) x <br /> <br />II <br />. <br /> <br />..., <br />I <br />. <br /> <br />,., <br />. <br /> <br />,., <br />. <br /> <br />,., <br />. <br /> <br />., <br />. <br /> <br />1 <br />. <br /> <br />II <br /> <br />. <br /> <br />II <br /> <br />r"""I <br /> <br />100, <br /> <br />. <br /> <br />where: <br /> <br />ro, <br /> <br />F = 4.4 + 39.1 (In x) -3.1 (In X)2 (Type I Cement) <br />F = -17.8 + 46.3 (In x) -3.3 (In X)2 (Type II Cement) <br />F 48.5 + 19.4 (In x) -1.4 (In x)2(Type III Cement) <br /> <br />. <br /> <br />., <br /> <br />x number of days since the concrete was placed <br />In = natural log <br />346-11.6.2 Pozzolanic-Cement Concrete: <br />Equivalent 28-day compressive strength f'e (28), where: <br /> <br />....., <br />. <br /> <br />. <br /> <br />. <br /> <br />( 8.31 )"276 <br />f'e (28) == 0.490 x f'e (t)x e f (Type I Cement) <br /> <br /> <br />f'e(28) = 0.730xf'e (t)xee':9)"'14 (Type II Cement) <br /> <br /> <br />f'e (28) = 0.483 x f'e (t)x )5.~8r91 <br /> <br />(Type III Cement) <br /> <br />II <br /> <br />. <br /> <br />I' <br /> <br />.., <br /> <br />. <br /> <br />r'I <br /> <br />09/09 <br /> <br />01000-107 <br /> <br />03-4122.F <br /> <br />. <br />
The URL can be used to link to this page
Your browser does not support the video tag.