Laserfiche WebLink
.) <br /> <br /> <br />..... Ardarmn & Associates, Inc. ([j) I <br />=.::.:..a.::.: C'roochicaJ. EnvirCXlTerla ad HAD 0 N N E <br />~ Mltenas CorIsUlarts <br /> <br />December 2, 2011 <br />City of Sunny Isles Beach <br />Request for Qualifications <br />Civil Engineering Services to Design <br />Street and Drainage Improvements <br />RFQ No.: 11-11-02 <br />Page 9 <br /> <br />SYSTEMS <br />~ <br /> <br />Experience with Similar Projects <br />Coastal Systems has a broad range of capabilities specializing in civil engineering services throughout <br />South Florida. This experience includes the planning and design of urban, barrier island stormwater <br />management systems as summarized in the following pages. <br /> <br /> <br />) <br /> <br /> <br /> <br /> <br />Capri Southbeach Streetscape, Miami Beach, Florida <br />Coastal Systems provided streetscape design services to improve <br />the Right-of-Way for 16th Street and Lincoln TeITace street ends as <br />part of the Capri South Beach Project. Capri South Beach <br />encompasses three (3) distinctive buildings on nearly 500 feet of <br />watetfront on Biscayne Bay. The streetscape improvements <br />included decorative pavers along with parking, sidewalks and <br />landscaping to accommodate adjacent residences as part of the <br />overall neighborhood improvements. <br /> <br />Prior to construction of the streetscape, Coastal Systems designed <br />underground utilities. The Lincoln TeITace street end is <br />approximately 325 feet long and required the design of a 12-inch <br />water main extension. Similarly, the 16th Street extension is <br />approximately 400 feet long, and required an 8-inch water main <br />extension as well as the slip lining of an existing 8-inch sanitary <br />sewer line. Both street ends were low in elevation and adjacent to <br />the bay and presented challenges for the drainage design. Detailed <br />topographic surveys were obtained to determine the drainage area <br />for the Right-of-Way for use in the hydrology study. Several <br />options were evaluated and an inverted-crown configuration for <br />the street ends was selected. The drainage improvements included <br />the design of stormwater pumping stations connected to outfalls <br />with associated controls and structures. <br /> <br />Corporate Office: 464 South Dixie Highway. Coral Gables, Florida 33146. Tel: 305.661-3655. Fax: 305-661-1914 <br />Regional Office: 2047 Vista Parkway, Suite 101. West Palm Beach, Florida 33411 . Tel, 561-640-1003 . Fax: 561-640-1009 <br />www.coastalsvstemsint.com.info@?coastals}.stemsint.com <br />