My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
SRS
SIBFL
>
City Clerk
>
Bids-RFQ-RFP
>
RFQ
>
(12-04-02) Professional Architectural and Engineering Services - Firms Only
>
Responses
>
SRS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/22/2012 10:22:41 AM
Creation date
5/22/2012 10:18:17 AM
Metadata
Fields
Template:
CityClerk-Bids_RFP_RFQ
Project Name
Prof. Architectural & Engin. Svcs
Bid No. (xx-xx-xx)
12-04-02
Project Type (Bid, RFP, RFQ)
RFQ
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RELEVANT EXPERIENCE <br />PROJECT NAME: City of Hialeah Annex <br />Area - Water and <br />Sewer <br />CLIENT'S NAME: City of Hialeah <br />Water & Sewer Dept. <br />Armando Vidal, P.E. <br />(305) 556 -3800 <br />TYPE OF FACILITY City of Hialeah <br />OR SERVICES: Annex Area <br />Water & Sewer <br />Improvements <br />SRS PROJECT FEE: $420,358 <br />COMPLETION DATE: February 2006 to <br />July 2007 <br />KEY INDIVIDUALS Ignacio Serralta, P.E. <br />INVOLVED: Oliverio Sanchez. P.E. <br />Jean - Claude Fontaneau <br />Orestes Rodriguez <br />PROJECT DESCRIPTION: <br />This project consisted of the engineering design <br />of water and sewer infrastructure required to <br />serve the newly annexed area to the City of <br />Hialeah. This work included the preparation of <br />construction documents and permitting assistance <br />to the City. Our work included the preparation of <br />a water and sewer master plan for the area in <br />order to determine the current and future service <br />needs and the size and location /alignment of <br />water and sewer main lines needed along the <br />major arterial roadways. It also included the <br />design of a regional sewer pump station with <br />backup generator with sufficient capacity to serve <br />the entire annexed and adjacent areas. <br />Additional work included the design of <br />approximately 1,480 LF of 24 -inch gravity <br />sanitary sewer mains, approximately 10,724 LF of <br />24 -inch force main extensions, approximately <br />3,229 LF of 36 -inch force main extensions, and <br />approximately 12,166 LF of 36 -inch water main <br />extensions. <br />(SRS was Prime Consultant) <br />•:7 <br />e ►: <br />ENOINEERINO,INC. <br />
The URL can be used to link to this page
Your browser does not support the video tag.