Laserfiche WebLink
Jose Lizasoain, P.E., CxA <br />Project Manager / Mechanical Engineer <br /> <br />2010, Orlando Science Center HVAC, Lighting, Power, Plumbing & Fire Protection Energy Assessment, Orlando, FL <br />– Mr. Lizasoain was a Mechanical Engineer commissioned to provide engineering services to identify and recommend the <br />best and most economical and energy efficient method of correcting the HVAC equipment located at the Orlando Science <br />Center Complex. Responsibilities included: operation and the deficiencies associated with the operation. Inspect the <br />facilities in areas of HVAC, lighting, power, Fire Alarm, security system, Plumbing & FP system. Review the as-build and <br />compare with actual conditions to learn more about the operation. Attend meetings with MRI, City PM and owner’s rep to <br />coordinate the activities and review SGM’s findings. Identify all the deficiencies associated with building’s HVAC, lighting, <br />power, fire alarm, plumbing & FP systems. Provide a break down and inspection report including executive summary <br />outlining the cost and improvement plan for the building operation. <br />2010, Orange County Medical Examiners Facility Orlando, FL – Mr. Lizasoain provided engineering services for <br />mechanical systems. Our fire protection submittal included complete sprinkler layout, specifications, and hydraulic <br />calculations. The plumbing drawings show required pipe routing and sizes supplying each plumbing fixture. In addition, <br />specifications were provided to show the required product materials, equipment, execution, and testing for all system s being <br />used. Our contract also included construction administration which required periodic site inspections, shop drawing review, <br />RFI responses, and meeting with the AHJ. <br />2010, Orange County Convention Center Orlando, FL – Mr. Lizasoain provided Mechanical Design and Commissioning <br />of new Variable Frequency Drives and Controls for all existing air handling units, fan, blowers and secondary chilled water <br />pumps. SGM was the Engineer of the record and responsible for a solid commissioning plan for this 4,200,000 sq. ft. facility, <br />the second largest convention center in the nation. The new plan was an alteration to existing facilities HVAC system. As <br />part of this project, SGM is currently upgrading and replacing the existing multi manufacturer HVAC building automation <br />systems (BAS) to the most current hardware and software using one manufacturer’s product. This BAS will be integrated <br />through an enterprise level portal with remote accessibility. The goal was to integrate the campus wide buildings into one <br />BAS web based access point.SGM is responsible for design of new controls, energy management system in compliance <br />with codes, development of specifications, sequence of controls, design and general construction scheduling, cost <br />estimating, and construction management. <br />2010, Orlando Events Center Parking Garage, Orlando, FL –Mr. Lizasoain provided Mechanical services for a $34 million <br />parking structure to serve the needs of the Orlando Events Center (OEC). The multi-level, open parking structure will feature <br />an estimated 2,000 spaces free of column obstacles, a helicopter landing pad, a climate-controlled elevated pedestrian <br />crosswalk to the Orlando Events Center, and an energy-efficient lighting system. The structure will have eight (8) elevated <br />parking levels. All stall sizes with be a minimum of 9’ wide and 18’ deep. The project is fast tracked for completion by July <br />2010. <br />2008, Orange County Convention Center, Roof Replacement, Orlando, FL – Mr. Lizasoain was a Mechanical Engineer <br />for this project. SGM was commissioned through a continuing contract to design and located Mechanical and Plumbing <br />Engineering component to the various roof areas. The scope includes the redesigning of the roof drains, sizing roof drains, <br />and routing storm drain piping. Also, decommissioned and recommissioned HVAC and Plumbing equipment during <br />scheduled roof replacements. <br />2007, City of Titusville, Fire Command Center, Titusville, FL – Mr. Lizasoain was a Mechanical Engineer for the building <br />assessment report regarding the MEP conditions of the City of Titusville’s Fire Command Center. SGM determined and <br />identified current issues for life safety, ADA, HVAC, IAQ and power/electric systems. SGM also prepared cast estimates for <br />associated deficiencies that were outlined in the report. The City utilized the report to request funding based on the findings. <br />2007, Orange County Corrections Central Utility Plant Chiller Expansion, Orlando, FL – Mr. Lizasoain provided <br />mechanical design services for the existing central chiller plant which was required to meet the campus HVAC needs. <br />2007, City of New Port Richey Recreation and Aquatic Center, New Port Richey, FL – Mr. Lizasoain provided <br />mechanical design services for the renovation of the thirty-seven year old existing recreation center and addition of a new <br />37,000 SF complex with a gymnasium, locker rooms, fitness center and meeting rooms. Exterior lighting was added for the <br />outdoor tennis courts, parking lots, basketball courts, shuffleboard courts, and walking trails. <br />